Disinfection of impression materials is recommended for preventing cross-contamination in dental clinics. However, aspects of the evaluation of elastomeric impression materials only slightly subjected to the effects of disinfectants have not been established. Therefore, the effects of sodium hypochlorite, glutaral, iodine, and ethanol disinfectants on elastomeric impression materials, condensation silicone, polysulfide, addition-type silicone (vinyl silicone), hydrophilic vinyl silicone, and polyether, were evaluated directly in a time-dependent manner by a non-contact displacement meter. Condensation silicone impression materials and polysulfide rubber impression materials greatly shrank over time, but their shrinkage decreased with immersion in disinfectants. Vinyl silicone impression materials and polyether impression materials showed excellent dimensional stability in air. However, hydrophilic vinyl silicone impression materials and polyether impression materials expanded greatly when immersed in disinfectants, especially when immersed in ethanol. Hydrophobic vinyl silicone impression materials showed excellent dimensional stability regardless of the presence or absence of disinfectants.
为防止牙科诊所内的交叉污染,建议对印模材料进行消毒。然而,对于仅轻微受消毒剂影响的弹性印模材料的评估方面尚未确立。因此,通过非接触式位移计以时间依赖性方式直接评估了次氯酸钠、戊二醛、碘和乙醇消毒剂对弹性印模材料(缩合型硅橡胶、聚硫橡胶、加成型硅橡胶(乙烯基硅橡胶)、亲水性乙烯基硅橡胶和聚醚)的影响。缩合型硅橡胶印模材料和聚硫橡胶印模材料随时间大幅收缩,但浸泡在消毒剂中时其收缩率降低。乙烯基硅橡胶印模材料和聚醚印模材料在空气中表现出优异的尺寸稳定性。然而,亲水性乙烯基硅橡胶印模材料和聚醚印模材料浸泡在消毒剂中时会大幅膨胀,尤其是浸泡在乙醇中时。疏水性乙烯基硅橡胶印模材料无论是否存在消毒剂均表现出优异的尺寸稳定性。