Bresciani C, Lebuisson D A, Eveillard M, Grossiord J L, Drupt F, Montefiore G
C.M.C. Foch, Service d'Ophtalmologie, Suresnes Cedex.
J Fr Ophtalmol. 1996;19(1):39-50.
To demonstrate the utility of a viscoelastic substance which maintains high viscosity during phacoemulsification, we conducted a double study.
We compared in vitro the corneal endothelial protection offered by Healon, Healon GV, Provisc and Viscoat after <
Corneal endothelial cell damage averaged 31.67% in eyes in which no viscoelastic substance was used. Damage was 14.29% in specimens that received Healon, 12.85% with Healon GV, 2.48% in the Viscoat group and 15.43 in those that received Provisc. There is a significant difference (p <0.001) between the Viscoat group and all other samples. The values of the viscosity at different shear rates and the graph of viscosities as a function of shear rate of the four viscous solutions are given.
Viscoat has a very high dynamic viscosity at high shear rate. This property and a poor cohesion provide a better corneal endothelial protection during in vitro phacoemulsification.
为了证明一种在超声乳化过程中保持高粘度的粘弹性物质的效用,我们进行了一项双盲研究。
我们在体外比较了Healon、Healon GV、Provisc和Viscoat在创伤性超声乳化术后对角膜内皮的保护作用。对8组每组10至15只新鲜摘除的猪眼进行手术;前四组为对照组,另外四组测试不同的粘性溶液。同时,我们在物理实验室测定了四种粘弹性物质的流变学特性。为了测量角膜内皮细胞损伤的百分比,我们使用了Janus Green光谱技术。
未使用粘弹性物质的眼中角膜内皮细胞损伤平均为31.67%。接受Healon的标本中损伤为14.29%,Healon GV为12.85%,Viscoat组为2.48%,接受Provisc的为15.43%。Viscoat组与所有其他样本之间存在显著差异(p<0.001)。给出了四种粘性溶液在不同剪切速率下的粘度值以及粘度随剪切速率变化的曲线。
Viscoat在高剪切速率下具有非常高的动态粘度。这一特性和较差的内聚力在体外超声乳化过程中提供了更好的角膜内皮保护。