• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Implantable artificial lung. Preliminary report.

作者信息

Morin P J, Gosselin C, Picard R, Vincent M, Guidoin R, Nicholl C I

出版信息

J Thorac Cardiovasc Surg. 1977 Jul;74(1):130-6.

PMID:875430
Abstract

The ultimate treatment of chronic respiratory insufficiency is pulmonary replacement by an artificial organ, homologous lung transplantation, or chronic paracorporeal respiratory supplementation. The woven capillary membrane oxygenator appears to be a major development toward implantable artificial organs. The four units tested are made up of screens 3.5 by 4.0 cm. of capillary tubing 0.3 mm. I.D. by 0.64 mm. O.D. assembled into rectangular blocks. Units made up by five, ten, twenty, and forty screens have been assembled and tested according to the protocol suggested by Galletti. The maximum oxygen transfer rate with blood was 48 ml. per minute per square meter. Water carbon dioxide transfer rate was 23.1 ml. per minute per square meter. The pressure drops in the liquid phase were 8.5, 15.3, 13.8, 17.6 mm. Hg at 1 L. per minute flow. These results indicate that the woven capillary membrane lung is an acceptably efficient oxygenator. The characteristics of design and performance suggest that this oxygenator can be made to be implanted into the chest or used as a paracorporeal respiratory assistance device.

摘要

相似文献

1
Implantable artificial lung. Preliminary report.
J Thorac Cardiovasc Surg. 1977 Jul;74(1):130-6.
2
Landé-Edwards membrane oxygenator without pump as total lung prosthesis.
J Thorac Cardiovasc Surg. 1975 Feb;69(2):196-202.
3
[Artificial "membranous lung"].[人工“膜肺”]
Med Tekh. 1976 Jul-Aug(4):44-50.
4
Development of an implantable artificial lung.
J Thorac Cardiovasc Surg. 1973 Oct;66(4):521-5.
5
Development of an intravenous membrane oxygenator: a new concept in mechanical support for the failing lung.静脉膜式氧合器的研发:用于衰竭肺脏机械支持的新概念。
J Heart Lung Transplant. 1994 Nov-Dec;13(6):1003-8.
6
[Use of a membrane oxygenator in respiratory assistance. I. Evaluation of the in vitro characteristics of the apparatus before use with blood].
Bull Physiopathol Respir (Nancy). 1972 Jan-Feb;8(1):7-28.
7
The toroidal membrane oxygenator: design, performance, and prolonged bypass testing of a clinical model.环形膜式氧合器:临床模型的设计、性能及长时间体外循环测试
Trans Am Soc Artif Intern Organs. 1972;18(0):369-74.
8
Bridge to lung transplantation through a pulmonary artery to left atrial oxygenator circuit.通过肺动脉至左心房氧合器回路建立肺移植桥梁。
Ann Thorac Surg. 2008 Apr;85(4):1202-5. doi: 10.1016/j.athoracsur.2007.12.032.
9
Pulsatile flow and oxygen transport past cylindrical fiber arrays for an artificial lung: computational and experimental studies.用于人工肺的通过圆柱形纤维阵列的脉动流与氧气传输:计算与实验研究
J Biomech Eng. 2008 Jun;130(3):031019. doi: 10.1115/1.2907752.
10
First experience with a paracorporeal artificial lung in humans.人体体外人工肺的首次应用经验。
ASAIO J. 2009 May-Jun;55(3):304-6. doi: 10.1097/MAT.0b013e31819740a0.