Summers R M, Feng D H, Holland S M, Sneller M C, Shelhamer J H
Department of Diagnostic Radiology, Henry M. Jackson Foundation, Warren Grant Magnuson Clinical Center, National Institutes of Health, Bethesda, MD 20892, USA.
Radiology. 1996 Sep;200(3):857-62. doi: 10.1148/radiology.200.3.8756944.
Computed tomography (CT) data sets obtained in 14 patients were used in a segmentation method for virtual bronchoscopy (VB). The method constrained the distance of propagation of a region-growing algorithm. The resulting three-dimensional bronchial model was a faithful representation of the source CT data and could be manipulated in real time at frame rates of one to two frames per second. Preliminary data showed that 90% of bronchi (up to third order) measureable on multiplanar CT reformations were also measurable at VB. The bronchial diameters measured at VB were within 1 mm of those measured on multi-planar reconstructions of the CT data.