Jacobs L B, Shirey R S, Ness P M
Department of Pathology, Johns Hopkins Hospital, Baltimore, MD 21287-6667, USA.
Arch Pathol Lab Med. 1996 Jul;120(7):684-6.
Hemolysis due to donor-derived antibodies produced by "passenger" B lymphocytes, called passenger lymphocyte syndrome, has been described in ABO-unmatched solid organ and bone marrow transplant recipients. Delayed hemolytic transfusion reactions occur within a similar time frame and have similar clinical and serologic findings. To our knowledge, we report the first case of hemolysis due to the simultaneous occurrence of passenger lymphocyte syndrome (donor-derived anti-A) and a delayed hemolytic transfusion reaction (recipient-produced anti-E) in a liver transplant patient.