Brandt J T, Barna L K, Triplett D A
Department of Pathology, Ohio State University, Columbus 43210, USA.
Thromb Haemost. 1995 Dec;74(6):1597-603.
Lupus anticoagulants (LAs) are antibodies that interfere with phospholipid dependent coagulation reactions in vitro. This workshop was designed to provide the participants with an experience in identification of LAs, to evaluate different criteria for mixing studies, to assess the performance of recently introduced confirmatory studies and to assess the performance of two potential surrogate LA control plasmas. The results demonstrate that there continues to be significant variation in the sensitivity and responsiveness of APTT reagents to the presence of LAs, confirming the need for more than one screening assay before the presence of a LA can be ruled out. In this workshop, the best distinction between factor deficiency and inhibitors was obtained using a 1:1 mix of normal plasma with patient plasma and the criterion defining correction as shortening of the APTT to within 5 s of the APTT of pooled normal plasma. A 4:1 mix of patient to normal plasma did not work well in distinguishing factor deficiency from inhibitors. The platelet neutralization procedure, DVV confirm and StaClot LA all gave positive results with the LA samples. False positive platelet neutralization procedures were seen with the samples from patients on oral anticoagulants and a factor V inhibitor. False positive StaClot LA results were obtained with high titer factor VIII inhibitors. Both of the potential surrogate plasmas gave variable results with multiple assays; they can not be recommended for routine use at present.
狼疮抗凝物(LAs)是在体外干扰磷脂依赖性凝血反应的抗体。本次研讨会旨在让参与者体验狼疮抗凝物的鉴定,评估混合试验的不同标准,评估最近引入的确证试验的性能,并评估两种潜在替代狼疮抗凝物对照血浆的性能。结果表明,活化部分凝血活酶时间(APTT)试剂对狼疮抗凝物存在的敏感性和反应性仍存在显著差异,这证实了在排除狼疮抗凝物存在之前需要进行不止一种筛查试验。在本次研讨会上,使用正常血浆与患者血浆1:1混合,并将APTT缩短至混合正常血浆APTT的5秒以内定义为纠正,在区分因子缺乏和抑制剂方面取得了最佳效果。患者血浆与正常血浆4:1混合在区分因子缺乏和抑制剂方面效果不佳。血小板中和试验、稀释蝰蛇毒时间(DVV)确证试验和StaClot LA试验对狼疮抗凝物样本均给出阳性结果。口服抗凝剂患者和因子V抑制剂患者的样本出现了血小板中和试验假阳性。高滴度因子VIII抑制剂出现了StaClot LA试验假阳性结果。两种潜在的替代血浆在多次试验中结果各异;目前不推荐将它们用于常规检测。