Chiou-Tan F Y, Vennix M J, Dinh T l, Robinson L R
Department of Physical Medicine and Rehabilitation, Baylor College of Medicine, Houston, Texas, USA.
Am J Phys Med Rehabil. 1996 Jul-Aug;75(4):278-82. doi: 10.1097/00002060-199607000-00008.
A complication of endoscopic carpal tunnel release (6/53 consecutive cases) is rupture of a digital branch. The objective of this study was to find a method for detecting neuropathy of the digital branch innervating the radial side of the fourth digit and the ulnar side of the third digit. This study examined whether the following sensory nerve conduction techniques would enhance diagnosis of this neuropathy: (1) recording with standard digital ring electrodes; (2) recording with ring electrodes from two adjacent fingers; and (3) disc electrodes placed between two fingers. Ten healthy individuals were studied before and after lidocaine anesthesia of the digital branch between the ring and middle finger. Statistical analysis was performed with a two-tailed, paired t test. Results show that after lidocaine injection there was a decrease in antidromic amplitude of 94% for ring electrodes on the fourth digit, 62% for rings on the third digit, 77% for disc electrodes between the fourth and third digits, and 74% for rings on digits 4 and 3 (P < 0.005), with no significant change in peak latency (P > 0.3). In conclusion, although all techniques used in this model yielded a significant change in amplitude, rings on the third digit compared with the second and discs between digits 4/3 compared with 3/2 were most specific without false-positives from normal data. It is hoped this study will aid the electromyographer in postoperative diagnosis.
内镜下腕管松解术的一种并发症(53例连续病例中的6例)是指神经分支断裂。本研究的目的是找到一种检测支配第四指桡侧和第三指尺侧的指神经分支神经病变的方法。本研究考察了以下感觉神经传导技术是否能增强对这种神经病变的诊断:(1)使用标准指环形电极记录;(2)使用环形电极从相邻的两个手指记录;(3)将盘状电极置于两个手指之间。对10名健康个体在利多卡因麻醉环指和中指之间的指神经分支前后进行了研究。采用双侧配对t检验进行统计分析。结果显示,注射利多卡因后,第四指环形电极的逆向波幅下降94%,第三指环形电极下降62%,第四和第三指之间的盘状电极下降77%,第四和第三指的环形电极下降74%(P<0.005),而峰潜伏期无显著变化(P>0.3)。总之,虽然本模型中使用的所有技术在波幅上都产生了显著变化,但与第二指相比,第三指的环形电极以及与3/2指相比,4/3指之间的盘状电极最具特异性,且正常数据无假阳性。希望本研究能有助于肌电图检查人员进行术后诊断。