Suppr超能文献

冷冻保存对人体动脉粘弹性特性的影响。

Effects of cryopreservation on the viscoelastic properties of human arteries.

作者信息

Rosset E, Friggi A, Novakovitch G, Rolland P H, Rieu R, Pellissier J F, Magnan P E, Branchereau A

机构信息

Department of Vascular Surgery, Saint Marguerite's Hospital, Marseille, France.

出版信息

Ann Vasc Surg. 1996 May;10(3):262-72. doi: 10.1007/BF02001892.

Abstract

The purpose of this study was to use our newly developed mock circulation loop to determine the effects of cryopreservation on the common carotid artery (CCA) and the superficial femoral artery (SFA). Fourteen healthy arteries (7 CCA and 7 SFA) harvested from multiple organ donors between the ages of 18 and 35 years were tested before and after cryopreservation at -140 degrees C using dimethyl sulfoxide and the vapor phase of liquid nitrogen. Mean storage time was 4.2 months. The mock pulse rate was 60 beats/min and the following four systolic/diastolic pressures settings were used: 50/110, 80/140, 110/170, and 140/200 mm Hg. Simultaneous measurements of intra-arterial pressure and external arterial diameter were made using an intra-arterial pressure sensor and external piezoelectric sensors. Measured data were used to calculate pulsatility, volumetric compliance, stiffness, midwall radial arterial stress, Young's modulus, and the incremental modulus. After SFA cryopreservation, no significant changes were observed. Conversely, CCA cryopreservation led to a significant decrease in compliance and pulsatility and a significant increase in stiffness. Young's modulus, the incremental modulus, and midwall radial arterial stress did not change significantly. A clearcut decrease in hysteresis was observed after cryopreservation in the CCA. No evidence of structural changes was detected on light and scanning electron microscopy. Baseline findings in this study were consistent with classification of the CCA as an elastic artery and the SFA as a muscular artery. Cryopreservation had no effect on the viscoelastic properties of muscular arteries (SFA). Cryopreservation affected only values related to the cylindrical shape of the elastic arteries (CCA). It had no effect on values related to wall structure.

摘要

本研究的目的是使用我们新开发的模拟循环回路来确定冷冻保存对颈总动脉(CCA)和股浅动脉(SFA)的影响。从18至35岁的多个器官捐献者处获取14条健康动脉(7条CCA和7条SFA),在使用二甲基亚砜和液氮气相于-140℃进行冷冻保存前后进行测试。平均保存时间为4.2个月。模拟脉搏率为60次/分钟,并使用以下四种收缩压/舒张压设置:50/110、80/140、110/170和140/200 mmHg。使用动脉内压力传感器和外部压电传感器同时测量动脉内压力和动脉外径。测量数据用于计算搏动性、容积顺应性、硬度、中膜径向动脉应力、杨氏模量和增量模量。SFA冷冻保存后,未观察到显著变化。相反,CCA冷冻保存导致顺应性和搏动性显著降低,硬度显著增加。杨氏模量、增量模量和中膜径向动脉应力没有显著变化。CCA冷冻保存后观察到滞后现象明显减少。在光镜和扫描电子显微镜下未检测到结构变化的证据。本研究中的基线结果与将CCA分类为弹性动脉和将SFA分类为肌性动脉一致。冷冻保存对肌性动脉(SFA)的粘弹性特性没有影响。冷冻保存仅影响与弹性动脉(CCA)圆柱形状相关的值。它对与血管壁结构相关的值没有影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验