Validation of a high-performance liquid chromatographic method for the determination of doxycycline in turkey plasma.

作者信息

Santos M D, Vermeersch H, Remon J P, Schelkens M, De Backer P, Ducatelle R, Haesebrouck F

机构信息

Laboratory of Pharmaceutical Technology, Faculty of Pharmaceutical Sciences, University of Ghent, Belgium.

出版信息

J Chromatogr B Biomed Appl. 1996 Jul 12;682(2):301-8. doi: 10.1016/0378-4347(96)00076-x.

Abstract

A high-performance liquid chromatographic method for the analysis of doxycycline in turkey plasma samples using demeclocycline hydrochloride as the internal standard was developed, optimized and validated. A one-step extraction procedure and an isocratic HPLC method with UV detection were used. No interferences with endogenous compounds or with the anticoagulant were observed. Linear calibration curves (r2 > 0.99) were obtained in water and plasma between 0 and 600 micrograms ml-1. Good recoveries for doxycycline (> 66%) and demeclocycline (> 72%) were seen both in water and in plasma. The coefficient of variation was < 9.86% for within-day reproducibility and < 7.53% for the between-day reproducibility. The deviation between the mean value found and the true value was < 14.5% (accuracy). The limit of detection was 0.1 microgram ml-1 in plasma samples. A good stability of doxycycline was observed in water and in plasma samples after storage for six months at -20 degrees C (recovery > 91%).