• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Evaluation of factors affecting bonding rate of calcium phosphate ceramic coatings for in vivo strain gauge attachment.

作者信息

Szivek J A, Anderson P L, Dishongh T J, DeYoung D W

机构信息

Department of Surgery, University of Arizona, Tucson 85724, USA.

出版信息

J Biomed Mater Res. 1996 Fall;33(3):121-32. doi: 10.1002/(SICI)1097-4636(199623)33:3<121::AID-JBM1>3.0.CO;2-S.

DOI:10.1002/(SICI)1097-4636(199623)33:3<121::AID-JBM1>3.0.CO;2-S
PMID:8864883
Abstract

The aim of this study was to compare the bone-bonding rates of eight calcium phosphate ceramic (CPC) coatings attached to strain gauges, alone and in conjunction with an OP1 device (Creative BioMolecules, Hopkinton, MA) and autologous concentrated pericyte cells. These coatings were studied to develop faster bone bonding to long-term in vivo strain sensors. Characterization of the CPC powders using electron microscopy and X-ray diffraction showed that they had shapes ranging from spherical to rocklike and properties ranging from highly crystalline to amorphous. CPC coated gauges were placed on the femora of young male dogs during aseptic surgery and were initially held in place using resorbable sutures. Test groups were euthanized after 3, 9, and 12 weeks. Both femora of the dogs were explanted and cantilever loaded. Response of the implanted hydroxyapatite (HA) coated gauges were compared to the response of bench-top glued sets of gauges (controls) attached to the contralateral femur and reported as a percentage of the control values. One CPC coating type showed an average response of 30% of controls after 3 weeks, four showed average responses higher than 75% after 9 weeks, and three showed averages higher than 82% after 12 weeks in vivo. Amorphous CPC coatings bonded more quickly than crystalline ones and particle shape had less effect than crystal structure on bonding rates. When either OP1 or autologous concentrated pericyte cells were placed on selected CPC coated gauge surfaces, the CPC5 coated gauges bonded best after 3 weeks with a response of 59%. After the same time period in vivo, CPC3 and CPC7 provided responses of 40 and 16%, respectively. Comparison of a soluble calcium-coated CPC with an uncoated one that had identical crystal structure and similar particle shape indicated that the calcium coating slowed bone bonding substantially in the young dog model. Optical microscopy of stained undecalcified bone sections and backscattered electron imaging indicated bone formation at all bone-HA interfaces and an increase in the number of areas of bone remodeling adjacent to the gauge at all time periods. Gross bone remodeling due to strain gauge placement was only observed near the distalmost cell-seeded strain gauges. Selection of the type of coating and enhancement system can accelerate bone bonding to strain sensors but must be tailored to the bone of the model in which it is being used. Augmentation of CPC coatings with cells or OP1 resulted in variable enhancement of the bonding rate and depended on the CPC and the enhancement system.

摘要

相似文献

1
Evaluation of factors affecting bonding rate of calcium phosphate ceramic coatings for in vivo strain gauge attachment.
J Biomed Mater Res. 1996 Fall;33(3):121-32. doi: 10.1002/(SICI)1097-4636(199623)33:3<121::AID-JBM1>3.0.CO;2-S.
2
Hydroxyapatite-coated strain gauges for long-term in vivo bone strain measurements.用于长期体内骨应变测量的羟基磷灰石涂层应变片。
J Appl Biomater. 1993 Summer;4(2):143-52. doi: 10.1002/jab.770040205.
3
In vivo strain measurements collected using calcium phosphate ceramic-bonded strain gauges.使用磷酸钙陶瓷粘结应变片收集的体内应变测量数据。
J Invest Surg. 1997 Sep-Oct;10(5):263-73. doi: 10.3109/08941939709032165.
4
Transforming growth factor-beta1 accelerates bone bonding to a blended calcium phosphate ceramic coating: a dose-response study.转化生长因子-β1促进骨与磷酸钙混合陶瓷涂层的结合:一项剂量反应研究。
J Biomed Mater Res A. 2004 Mar 1;68(3):537-43. doi: 10.1002/jbm.a.20099.
5
Bone bonding strength of calcium phosphate ceramic coated strain gauges.磷酸钙陶瓷涂层应变片的骨结合强度
J Biomed Mater Res. 1999 Spring;48(1):32-5. doi: 10.1002/(sici)1097-4636(1999)48:1<32::aid-jbm7>3.0.co;2-x.
6
Surface enhancements accelerate bone bonding to CPC-coated strain gauges.表面增强可加速骨与磷酸钙骨水泥涂层应变片的结合。
J Biomed Mater Res. 2001 Jul;56(1):109-19. doi: 10.1002/1097-4636(200107)56:1<109::aid-jbm1075>3.0.co;2-w.
7
Interface strength studies of calcium phosphate ceramic coated strain gauges.磷酸钙陶瓷涂层应变片的界面强度研究
J Biomed Mater Res. 1998 Winter;43(4):462-8. doi: 10.1002/(sici)1097-4636(199824)43:4<462::aid-jbm14>3.0.co;2-j.
8
A comparison of in vitro and in vivo degradation of two CPC strain gauge coatings.两种磷酸钙骨水泥应变片涂层的体外和体内降解比较。
J Biomed Mater Res. 2000;53(3):211-5. doi: 10.1002/(sici)1097-4636(2000)53:3<211::aid-jbm4>3.0.co;2-5.
9
Comparison of plasma-sprayed hydroxyapatite coatings and hydroxyapatite/tricalcium phosphate composite coatings: in vivo study.等离子喷涂羟基磷灰石涂层与羟基磷灰石/磷酸三钙复合涂层的比较:体内研究
J Biomed Mater Res. 2001 Jun 5;55(3):360-7. doi: 10.1002/1097-4636(20010605)55:3<360::aid-jbm1040>3.0.co;2-q.
10
Preliminary development of a hydroxyapatite-backed strain gauge.
J Appl Biomater. 1990 Fall;1(3):241-8. doi: 10.1002/jab.770010307.

引用本文的文献

1
Osseosurface electronics-thin, wireless, battery-free and multimodal musculoskeletal biointerfaces.骨表面电子器件——轻薄、无线、无电池且具备多模态的肌肉骨骼生物接口。
Nat Commun. 2021 Nov 18;12(1):6707. doi: 10.1038/s41467-021-27003-2.
2
Selective cell proliferation can be controlled with CPC particle coatings.可通过磷酸钙骨水泥颗粒涂层来控制细胞的选择性增殖。
J Biomed Mater Res A. 2007 Jun 15;81(4):939-47. doi: 10.1002/jbm.a.31116.