Suppr超能文献

基于美国政府工业卫生学家会议(ACGIH)和职业安全与健康管理局(OSHA)推荐的噪声标准,对一个工作场所的每日噪声暴露情况进行比较。

Comparison of daily noise exposures in one workplace based on noise criteria recommended by ACGIH and OSHA.

作者信息

Petrick M E, Royster L H, Royster J D, Reist P

机构信息

IBM Corporation, Research Triangle Park, NC 27709, USA.

出版信息

Am Ind Hyg Assoc J. 1996 Oct;57(10):924-8. doi: 10.1080/15428119691014440.

Abstract

The objective of this study was to determine the impact of the new American Conference of Governmental Industrial Hygienists (ACGIHnew) noise criteria, as compared to the current U.S. Occupational Safety and Health Administration (OSHA) hearing conservation criteria, on the number of employees to be included in the hearing conservation program at one industrial facility. This study also compares the combined effects of a 3-dB versus a 5-dB exchange rate and an 80-dBA versus a 90-dBA measurement threshold on daily noise doses and equivalent 8-hr time-weighted averages (TWAs). Employee noise exposures were measured using paired Ametek MK-3 noise dosimeters, one dosimeter set to the ACGIHnew noise criteria and one to the present OSHA hearing conservation criteria. Samples were collected over 4-hr periods (half-shifts) for 50 employees in 7 job categories. Results indicate that the majority of the employees' exposures fell below an 8-hr TWAOSHA of 85 dBA. The differences between the predicted TWAACGIHnew and the TWAOSHA ranged between 0.2 and 12.6 dB for paired samples, with an average difference of 4.6 dB. Overall, these differences in employee 8-hr TWAs would project a 36% increase in the percent of the population enrolled in the hearing conservation program and a 50% increase in the percent of the population required to wear hearing protection.

摘要

本研究的目的是确定与美国现行职业安全与健康管理局(OSHA)听力保护标准相比,美国政府工业卫生学家会议(ACGIH)新的噪声标准对某一工业设施中纳入听力保护计划的员工数量的影响。本研究还比较了3分贝与5分贝交换率以及80分贝与90分贝测量阈值对每日噪声剂量和等效8小时时间加权平均值(TWA)的综合影响。使用配对的Ametek MK-3噪声剂量计测量员工的噪声暴露情况,一个剂量计设置为ACGIH新的噪声标准,另一个设置为现行的OSHA听力保护标准。对7个工作类别的50名员工在4小时时间段(半个班次)内进行了样本采集。结果表明,大多数员工的暴露水平低于OSHA规定的8小时TWA 85分贝。配对样本的预测TWAACGIH新值与TWAOSHA值之间的差异在0.2至12.6分贝之间,平均差异为4.6分贝。总体而言,员工8小时TWA的这些差异预计将使纳入听力保护计划的人口百分比增加36%,使需要佩戴听力保护装置的人口百分比增加50%。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验