Trabaud M A, Bailly F, Colucci G, Trepo C
Unité de recherche sur les hépatites, le SIDA et les rétrovirus humains (INSERM U271), Lyon, France.
J Viral Hepat. 1996 Jul;3(4):207-9. doi: 10.1111/j.1365-2893.1996.tb00097.x.
Recovery of hepatitis C virus (HCV) RNA, after variable time intervals from collection, was assessed using a closed-tube system for collection, separation and transport (SST tubes). Blood from four hepatitis C-infected patients was collected in 12 SST tubes and centrifuged within 1 to 3 h of collection. Tubes were then left 0, 8, 12, 24, 48 and 72 h at room temperature and at 4 degrees C before removing serum. Hepatitis C virus RNA levels were measured by quantitative polymerase chain reaction (PCR) using the AMPLICOR HVC MONITOR assay. Hepatitis C virus RNA levels in these samples were stable for at least three days at both temperatures. Polymerase chain reaction signals never decreased by more than 0.5 log. The reproducibility of the assays showed that the quantitative PCR method can be used with the storage conditions tested here. Our data suggests that processing blood in SST tubes may be very useful in following hepatitis C virus RNA titres in infected patients, especially those receiving treatment.
使用用于采集、分离和运输的封闭管系统(SST管),评估采集后不同时间间隔的丙型肝炎病毒(HCV)RNA的回收率。从4名丙型肝炎感染患者采集的血液被收集到12个SST管中,并在采集后1至3小时内进行离心。然后在去除血清之前,将试管分别在室温及4℃下放置0、8、12、24、48和72小时。使用AMPLICOR HVC MONITOR检测法通过定量聚合酶链反应(PCR)测量丙型肝炎病毒RNA水平。这些样本中的丙型肝炎病毒RNA水平在这两个温度下至少三天保持稳定。聚合酶链反应信号从未下降超过0.5个对数。检测的可重复性表明,定量PCR方法可用于此处测试的储存条件。我们的数据表明,在SST管中处理血液对于追踪感染患者尤其是接受治疗患者的丙型肝炎病毒RNA滴度可能非常有用。