Abstract

To achieve accurate blood pressure measurement through radial artery catheters in infants, we previously developed an experimental high-fidelity catheter-manometer system (CMS). As this system lacks facilities for flushing and for blood sampling, we aimed to further develop this technique in order to make the system suitable for clinical practice. In addition, we aimed to develop methods to automate processing of the pressure wave forms. The high-fidelity system to be improved consisted of a 24 Gauge catheter, a threeway stopcock and a tip-manometer. We inserted this system in the catheter-manometer system as routinely used i.e. the remaining end of the stopcock was connected to the fluid-filled CMS as used routinely. This combined system became clinically applicable, since blood samples could be obtained and flushing could be performed. The measurement chain was completed by application of a modified physiological monitor and a computerized method to analyze pressure wave forms. In this manner accurate beat-to-beat pressure parameters were obtained. This technique was applied to 25 neonates admitted for intensive care and requiring arterial access. Gestational age of these infants ranged from 25-40 (median 29) weeks and birth weight ranges from 500-3375 (median 1060) grams. In all infants the technique was found to be convenient and the high-fidelity blood pressure measurements were performed without any problems. The advantage of the present system is the potential for both correct intermittent recordings of arterial wave forms in close relation to clinical condition and for the establishment of accurate radial artery beat-to-beat pressure values in clinical practice.

摘要

为了通过婴儿桡动脉导管实现准确的血压测量,我们之前开发了一种实验性的高保真导管-压力计系统(CMS)。由于该系统缺乏冲洗和采血设施,我们旨在进一步改进这项技术,以使该系统适用于临床实践。此外,我们旨在开发自动处理压力波形的方法。有待改进的高保真系统由一根24号导管、一个三通旋塞和一个尖端压力计组成。我们将该系统按照常规方式插入导管-压力计系统,即旋塞的另一端连接到常规使用的充满液体的CMS上。这个组合系统变得适用于临床,因为可以采集血样并进行冲洗。通过应用改良的生理监测仪和一种计算机化方法来分析压力波形,测量链得以完善。通过这种方式获得了准确的逐搏血压参数。这项技术应用于25名因重症监护而入院且需要动脉通路的新生儿。这些婴儿的胎龄为25 - 40(中位数29)周,出生体重为500 - 3375(中位数1060)克。在所有婴儿中,该技术都被证明是方便的,并且高保真血压测量没有任何问题。本系统的优点在于,它有可能既与临床状况密切相关地正确间歇性记录动脉波形,又能在临床实践中建立准确的桡动脉逐搏血压值。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验