Suppr超能文献

Transmembrane passage of cytokine-inducing bacterial products across new and reprocessed polysulfone dialyzers.

作者信息

Sundaram S, Barrett T W, Meyer K B, Perrella C, Neto M C, King A J, Pereira B J

机构信息

Department of Medicine, New England Medical Center Hospitals, Boston, MA 02111, USA.

出版信息

J Am Soc Nephrol. 1996 Oct;7(10):2183-91. doi: 10.1681/ASN.V7102183.

Abstract

The widespread use of bicarbonate dialysate and reprocessed high-efficiency and "high-flux" dialyzers has raised concerns about the increased risk of reverse-transfer of dialysate contaminants into the blood compartment. To evaluate this concern, the reverse-transfer of bacterial products from contaminated bicarbonate dialysate into the blood compartment was compared during in vitro dialysis with new or reprocessed high-flux polysulfone dialyzers. In vitro dialysis was carried out at 37 degrees C by use of a counter-current recirculating loop dialysis circuit with either new high-flux polysulfone dialyzers or dialyzers reprocessed once or 20 times with formaldehyde (0.75%) and bleach (< 1%) with an automated system. Heparinized whole blood from healthy volunteers was circulated through the blood compartment, and bicarbonate dialysate was circulated in the dialysate compartment. The dialysate was challenged sequentially by 1:1000 and 1:100 dilutions of a sterile Pseudomonas aeruginosa culture supernatant (bacterial challenge). Samples were drawn from the blood and dialysate compartments 1 h after each challenge. Peripheral blood mononuclear cells (PBMC) were harvested by Ficoll-Hypaque separation from whole blood in the blood compartment and a 5 x 10(6) PBMC/mL cell suspension was prepared. Likewise, dialysate samples (0.5 mL) were added to 0.5 mL suspension of 5 x 10(6) PBMC/mL drawn at baseline. All PBMC suspensions were incubated upright in a humidified atmosphere at 37 degrees C with 5% CO2 for 24 h, and total interleukin-1 alpha (IL-1 alpha) and tumor necrosis factor-alpha (TNF alpha) cytokine production (cell-associated and secreted) was measured by radioimmunoassay. Eight experiments were performed for each arm of the study with the same donor for each arm. One hour after contaminating the dialysate with a 1:1000 dilution of the bacterial challenge, IL-1 alpha production by PBMC harvested from the blood compartment was 160 +/- 0, 171 +/- 11, and 270 +/- 35 pg, respectively, for new dialyzers, dialyzers reprocessed once, and dialyzers reprocessed 20 times (P = 0.004). One hour after challenging the dialysate with 1:100 dilution, IL-1 alpha production by PBMC harvested from the blood compartment was 188 +/- 20, 228 +/- 35, and 427 +/- 67 pg, respectively, for new dialyzers, dialyzers reprocessed once, and dialyzers reprocessed 20 times (P = 0.006). IL-1 alpha production by PBMC from dialyzers reprocessed 20 times was significantly greater than both new and dialyzers reprocessed once. However, there were no significant differences between new dialyzers and dialyzers reprocessed once. Similarly, after the 1:1000 challenge, TNF alpha production by PBMC harvested from the blood compartment was 160 +/- 0, 160 +/- 0, and 213 +/- 22 pg, respectively, for new dialyzers, dialyzers reprocessed once, and dialyzers reprocessed 20 times (P = 0.008). After the 1:100 challenge, TNF alpha production was 168 +/- 8, 188 +/- 20, and 225 +/- 32 pg, respectively, for new dialyzers, dialyzers reprocessed once, and dialyzers reprocessed 20 times (P = 0.20). These results demonstrate that reprocessing of high-flux polysulfone dialyzers with bleach increases the risk of reverse-transfer of bacterial products from contaminated dialysate, and this risk appears to increase with the number of reuses. Consequently, units that reprocess membranes with bleach and have suboptimal water quality might subject their patients to a higher risk of cytokine-related morbidity.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验