Rectal mucosal electrosensitivity - what is being tested?

作者信息

Meagher A P, Kennedy M L, Lubowski D Z

机构信息

Colorectal Unit, St. George Hospital, Sydney, Australia.

出版信息

Int J Colorectal Dis. 1996;11(1):29-33. doi: 10.1007/BF00418852.

Abstract

The results of rectal mucosal electrosensitivity (RME) testing have been used to support theories regarding the aetiology of both idiopathic constipation and bowel dysfunction following rectopexy. The aim of this study was to assess the validity of tests of RME. Sixty-eight patients, comprising three groups (group 1: 50 patients undergoing assessment in the Anorectal Physiology Unit, group 2: 10 patients with coloanal or ileoanal anastomosis, group 3: 8 patients with a stoma) underwent mucosal electrosensitivity testing, with the threshold stimulus required to elicit sensation being recorded. In addition the RME was measured in groups 1 and 2 when placing the electrode, mounted on a catheter with a central wire, against the anterior, posterior, right and left rectal or neorectal walls. To asses the influence on this test of loss of mucosal contact due to faeces, a further 8 cases with a normal rectum had RME performed with and without a layer of water soaked gauze around the electrode to stimulate faeces and prevent the electrode from making contact with the rectal mucosa. There was marked variance in the sensitivity of the different regions of rectal wall tested (P < 0.001). In group 1 patients the mean sensitivities were: central 36.6 mA, anterior 27.4 mA, posterior 37.9 mA, right 22.3 mA and left 25.6 mA. This circumferential variation suggests that the pelvic floor rather than rectal mucosa was being stimulated. All patients in group 2 had recordable sensitivities, and the mean sensitivity threshold was significantly higher than group 1 patients in the central (P = 0.03), right (P = 0.03) and left (P = 0.007) positions. In group 3 the sensitivity was greater within the stoma at the level of the abdominal wall muscle than intra-abdominally or subcutaneously, again suggesting an extra-colonic origin of the sensation. The sensitivity threshold was significantly greater with the electrode wrapped in gauze (P < 0.01), and loss of mucosal contact was not detected by the EMG machine. Therefore RME testing would seem not to measure mucosal sensitivity, and is probably influenced by the presence of faeces.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验