Saadé C, Wüst T
Institut für Transfusions- und Laboratoriums-medizin, Städtisches Klinikum Pforzheim, Deutschland.
Infusionsther Transfusionsmed. 1996 Jun;23(3):133-7.
The aim of the continuous development of anti-HIV-ELISA tests is the improvement of their specificity and sensitivity. With this study the precision and the specificity of the Cobas Core Anti-HIV-1/HIV-2 DAGS, a 3rd-generation anti-HIV assay, were evaluated.
1,557 frozen and 1,654 fresh sera from blood donors were tested with the Cobas Core Anti-HIV-1/HIV-2 DAGS (Roche Diagnostic Systems, Basel, Switzerland) and the Abbott Recombinant HIV-1/HIV-2 3rd Generation EIA (Abbott GmbH Diagnostika, Wiesbaden, Germany), which was used as a reference assay. Positive sera were tested with a Westernblot. 34 sera, previously not negative in the Abbott test, were retested with the two anti-HIV assays and with a Westernblot. The intra- and inter-assay precision was evaluated with the positive and negative controls of the test kits and with control sera.
The intra- and inter-assay precision of the Roche test was very good. The specificity of the Roche test is 99.91%. Out of 3,211 tested sera those of three blood donors were false positive in the Roche test and one sample false positive in the Abbott test.
The precision and specificity of the new anti-HIV test fulfil the demands of transfusion medicine.
持续研发抗HIV-ELISA检测的目的是提高其特异性和灵敏度。本研究评估了第三代抗HIV检测试剂Cobas Core Anti-HIV-1/HIV-2 DAGS的精密度和特异性。
使用Cobas Core Anti-HIV-1/HIV-2 DAGS(罗氏诊断系统公司,瑞士巴塞尔)和雅培重组HIV-1/HIV-2第三代酶免疫测定法(雅培诊断有限公司,德国威斯巴登)对1557份来自献血者的冷冻血清和1654份新鲜血清进行检测,后者用作参考检测方法。对阳性血清进行免疫印迹检测。对34份先前在雅培检测中并非阴性的血清,用这两种抗HIV检测方法和免疫印迹法重新检测。通过检测试剂盒的阳性和阴性对照以及对照血清评估批内和批间精密度。
罗氏检测的批内和批间精密度非常好。罗氏检测的特异性为99.91%。在3211份检测血清中,有3名献血者的血清在罗氏检测中为假阳性,1份样本在雅培检测中为假阳性。
新型抗HIV检测的精密度和特异性满足输血医学的要求。