Suppr超能文献

超声检查作为一种确定肌腱横截面积的方法。

Ultrasonography as a method to determine tendon cross-sectional area.

作者信息

Gillis C, Sharkey N, Stover S M, Pool R R, Meagher D M, Willits N

机构信息

Veterinary Medical Teaching Hospital, University of California, Davis 95616, USA.

出版信息

Am J Vet Res. 1995 Oct;56(10):1270-4.

PMID:8928941
Abstract

Ultrasonographic cross sectional area (CSA) measurements of equine superficial digital flexor (SDF) tendon were obtained to determine the feasibility of ultrasonography for CSA measurement of tendon in vivo and in vitro. Ultrasonographic measurements were compared with a more traditional CSA measurement method, ink-blot analysis. In addition, values for ultrasonographic SDF tendon mean echogenicity were obtained in vivo and in vitro. The left forelimb SDF tendons of 23 horses were evaluated ultrasonographically. Cross sectional images were acquired at 4-cm intervals distal to the base of the accessory carpal bone (DACB) to the level of the proximal sesamoid bones while horses were standing squarely. After euthanasia, the left forelimbs were mounted in a materials testing system (MTS) and loaded under tension to standing load. Ultrasonographic images were again acquired at the same locations. The ultrasonographic images were digitized, and values for ultrasonographic CSA and mean echogenicity were obtained for each level. immediately after mechanical testing, a 1-cm-thick transverse section of SDF tendon at 12 cm DACB was removed. Three ink blots were prepared from each end of the removed tendon section and digitized. The 6 CSA values were averaged to generate a value for morphologic CSA for each SDF tendon at 12 cm DACB. Standing ultrasonographic tendon CSA at 12 cm DACB was consistently smallest (mean +/- SD CSA 86 +/- 11 mm2), followed by MTS ultrasonographic CSA (mean, 95 +/- 12 mm), with ink-blot morphologic CSA being largest (mean, 99 +/- 15 mm2). Comparison of standing and MTS ultrasonographic CSA values at 12 cm DACB revealed a strong positive linear correlation between methods (R2 = 0.74, P = 0.001). Comparison of ink blot CSA at 12 cm DACB with standing and MTS ultrasonographic CSA revealed strong positive linear correlations (R2 = 0.64, P = 0.001 and R2 = 0.72, P = 0.001, respectively). For ultrasonographic mean echogenicity, standing values insignificantly exceeded MTS values at each level. The authors conclude that ultrasonography is a useful technique for the noninvasive assessment of SDF tendon CSA that can be applied in vivo and in vitro.

摘要

获取马浅屈肌腱(SDF)的超声横截面积(CSA)测量值,以确定超声检查在体内和体外测量肌腱CSA的可行性。将超声测量结果与一种更传统的CSA测量方法——墨渍分析进行比较。此外,还获得了体内和体外超声SDF肌腱平均回声强度值。对23匹马的左前肢SDF肌腱进行了超声评估。当马正立时,在副腕骨(DACB)基部远端至近籽骨水平每隔4厘米获取横截面图像。安乐死后,将左前肢安装在材料测试系统(MTS)中,并在张力下加载至站立负荷。再次在相同位置获取超声图像。将超声图像数字化,并获取每个水平的超声CSA和平均回声强度值。机械测试后,立即在DACB 12厘米处取1厘米厚的SDF肌腱横切片。从取出的肌腱切片的每一端制备三个墨渍并数字化。将6个CSA值平均,以得出每个SDF肌腱在DACB 12厘米处的形态学CSA值。DACB 12厘米处站立时的超声肌腱CSA始终最小(平均±标准差CSA 86±11平方毫米),其次是MTS超声CSA(平均,95±12毫米),墨渍形态学CSA最大(平均,99±15平方毫米)。比较DACB 12厘米处站立和MTS超声CSA值发现,两种方法之间存在强正线性相关性(R2 = 0.74,P = 0.001)。比较DACB 12厘米处的墨渍CSA与站立和MTS超声CSA发现,存在强正线性相关性(分别为R2 = 0.64,P = 0.001和R2 = 0.72,P = 0.001)。对于超声平均回声强度,每个水平的站立值略高于MTS值。作者得出结论,超声检查是一种用于无创评估SDF肌腱CSA的有用技术,可应用于体内和体外。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验