Yoshizako T, Sugimura K, Kawamitsu H, Yoshikawa K
Department of Radiology, Shimane Medical University, Japan.
J Comput Assist Tomogr. 1996 Nov-Dec;20(6):957-64. doi: 10.1097/00004728-199611000-00017.
The purpose of this study was to determine the optimum imaging parameters for 2D-TOF MR venography (MRV) of the pelvis and suprapopliteal deep venous system in combination with off-resonance magnetization transfer constant (MTC) and to evaluate the use of MRV in patients suspected of having chronic deep venous thrombosis (DVT) by comparing its accuracy with that of conventional venography (CV).
MRV was performed in 10 normal subjects to determine the optimum imaging parameters. Systematically varied scan parameters included flip angles ranging from 30 to 120 degrees by 10 degrees increments. Best TR was calculated by using the theoretical relation between the optimal TR and flow velocity. We then evaluated the use of MRV in 26 patients (total 52 deep venous systems) suspected of having chronic DVT by comparing its accuracy in evaluating the intrapelvic and suprapopliteal deep venous system with that of CV.
The optimal imaging parameters for intrapelvic and suprapopliteal venous system MRV were found to be a flip angle of 60 degrees and a pulse sequence of 35/6.9 (TR ms/TE ms) combined with an off-resonance MTC technique. All the main veins of the intrapelvic and suprapopliteal venous systems were clearly demonstrated in each subject. The sensitivity of MRV was 100% and its specificity was 100% for diagnosis of pelvic venous stenosis. The collateral vessels were demonstrated with MRV in all patients.
2D-TOF off-resonance MTC MRV of the pelvis and the suprapopliteal lower extremities is suitable for evaluation of intrapelvic branches and suprapopliteal deep venous system and chronic DVT.
本研究的目的是确定骨盆和腘上深静脉系统二维时间飞跃法磁共振静脉血管造影(MRV)结合非共振磁化传递常数(MTC)的最佳成像参数,并通过将其准确性与传统静脉血管造影(CV)进行比较,评估MRV在疑似慢性深静脉血栓形成(DVT)患者中的应用。
对10名正常受试者进行MRV检查以确定最佳成像参数。系统变化的扫描参数包括翻转角,范围从30度到120度,以10度为增量。通过使用最佳TR与流速之间的理论关系计算最佳TR。然后,我们通过比较MRV与CV在评估盆腔内和腘上深静脉系统方面的准确性,评估了MRV在26例疑似慢性DVT患者(共52个深静脉系统)中的应用。
发现盆腔内和腘上静脉系统MRV的最佳成像参数为翻转角60度,脉冲序列为35/6.9(TR毫秒/TE毫秒),并结合非共振MTC技术。每个受试者盆腔内和腘上静脉系统的所有主要静脉均清晰显示。MRV诊断盆腔静脉狭窄的敏感性为100%,特异性为100%。所有患者的侧支血管均通过MRV显示。
骨盆和腘上下肢的二维时间飞跃法非共振MTC MRV适用于评估盆腔内分支和腘上深静脉系统以及慢性DVT。