Gabriel S, Lau R W, Gabriel C
Physics Department, King's College, Strand, London, UK.
Phys Med Biol. 1996 Nov;41(11):2251-69. doi: 10.1088/0031-9155/41/11/002.
Three experimental techniques based on automatic swept-frequency network and impedance analysers were used to measure the dielectric properties of tissue in the frequency range 10 Hz to 20 GHz. The technique used in conjunction with the impedance analyser is described. Results are given for a number of human and animal tissues, at body temperature, across the frequency range, demonstrating that good agreement was achieved between measurements using the three pieces of equipment. Moreover, the measured values fall well within the body of corresponding literature data.
采用了三种基于自动扫频网络和阻抗分析仪的实验技术,用于测量10 Hz至20 GHz频率范围内组织的介电特性。描述了与阻抗分析仪结合使用的技术。给出了多种人体和动物组织在体温下、整个频率范围内的测量结果,表明使用这三种设备进行的测量之间取得了良好的一致性。此外,测量值完全落在相应文献数据范围内。