Dubinina N I, Kurenbin O I, Tennikova T B
Institute of Macromolecular Compounds, Russian Academy of Sciences, St. Petersburg, Russia.
J Chromatogr A. 1996 Nov 15;753(2):217-25. doi: 10.1016/s0021-9673(96)00545-6.
Since the influence of column length on protein resolution in high-performance liquid chromatography (HPLC) is not clear, different viewpoints presented in the literature are analysed in detail. The influence of gradient steepness on the length of the working column part (X0) or the part of a column in which the quasi-steady state is attained was studied. The equation for estimating the X0 value was obtained for the general case of the retention model. It was shown that at steep gradients only a short part of the column is used as the working part on which all separation processes develop. The other part of a column is a ballast where the protein zone migrates in a regime of parallel transfer. These results form a theoretical basis for high-performance membrane chromatography. As was shown experimentally, this method makes it possible to perform protein separation at low gradient times with appropriate resolution, comparable with that of HPLC.
由于高效液相色谱(HPLC)中柱长对蛋白质分离度的影响尚不清楚,因此对文献中提出的不同观点进行了详细分析。研究了梯度陡度对工作柱部分(X0)或达到准稳态的柱部分长度的影响。针对保留模型的一般情况,得到了估算X0值的方程。结果表明,在陡峭梯度下,只有柱的一小部分用作所有分离过程发生的工作部分。柱的另一部分是平衡段,蛋白质区在其中以平行转移的方式迁移。这些结果为高效膜色谱奠定了理论基础。实验表明,该方法能够在低梯度时间下以与HPLC相当的分辨率进行蛋白质分离。