• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Technetium-99m-MAG3 renal studies in spinal cord injury patients: normal range, reproducibility, and change as a function of duration and level of injury.

作者信息

Klingensmith W C, Lammertse D P, Briggs D E, Smith W I, Roberts J F, Froelich J W, Sutherland J D

机构信息

Swedish Medical Center, Craig Rehabilitation Hospital, Englewood, Colorado, USA.

出版信息

Spinal Cord. 1996 Jun;34(6):338-45. doi: 10.1038/sc.1996.62.

DOI:10.1038/sc.1996.62
PMID:8963987
Abstract

UNLABELLED

The normal range, reproducibility, and change as a function of duration and level of injury for Tc-99m-MAG3 renal studies were quantitated in spinal cord injury (SCI) patients.

METHODS

Five SCI patients without evidence of renal disease in each of four groups: less than 2 months, 2-12 months, 1-2 years, and greater than 2 years from time of injury, were each studied twice. There were at least two patients with paraplegia and two with tetraplegia in each group. Renal clearance (camera based method), percent function in each kidney, time of peak renal parenchymal activity, and half time of parenchymal activity following the peak were evaluated. The peak and half times were determined with regions of interest (ROIs) over the entire kidney and over just the cortex. All results were compared to normal ranges previously established in normal subjects of the same age range using the same methodology.

RESULTS

Renal clearance in the less than 2 month SCI patients was not significantly different from normal subjects in either paraplegic or in tetraplegic individuals. However, clearance in tetraplegics was increased by 28.5% at 2-12 month, increased by 50.6% at 1-2 years, and decreased by 25.9% at greater than 2 years compared to normal subjects (all P < 0.02). Clearance in those with paraplegia showed a similar, but less marked, trend (P = NS). The time of peak parenchymal activity when measured with cortical ROIs did not vary among patient groups or level of injury, but was increased compared to normal subjects (P < 0.05). The percent function in each kidney and half time following the peak were symmetrical, did not differ among patient groups or with level of injury, and did not differ from normal subjects. The parenchymal peak time was significantly shorter with cortical rather than renal ROIs in all patient groups (P < 0.05). In serial studies in the same patient the percent standard deviation in total renal clearance was less than between single studies in different patients, but the decrease was significant for only the right kidney (P < 0.03), and the decrease was not as great as in normal subjects. In addition, the percent standard deviation for percent function in each kidney was significantly less than the percent standard deviations in single studies (P < 0.02). There were no significant differences between intra- and interpatient studies for any other parameter.

CONCLUSION

We conclude that: (1) renal clearance measured with Tc-99m-MAG3 in tetraplegic patients increases significantly during the first 2 years following injury and decreases significantly thereafter; there is a similar, but much less marked, trend in paraplegics, (2) parenchymal peak times with cortical ROIs occur later for SCI patients than for normal subjects, and (3) there is more intrapatient variation in total renal clearance and percent renal clearance on a side in SCI patients than in normal subjects suggesting that it may be harder to study SCI patients reproducibly. These findings should be taken into account when performing and interpreting Tc-99m-MAG3 renal studies in SCI patients.

摘要

相似文献

1
Technetium-99m-MAG3 renal studies in spinal cord injury patients: normal range, reproducibility, and change as a function of duration and level of injury.
Spinal Cord. 1996 Jun;34(6):338-45. doi: 10.1038/sc.1996.62.
2
Technetium-99m-MAG3 renal studies: normal range and reproducibility of physiologic parameters as a function of age and sex.锝-99m-巯基乙酰三甘氨酸肾动态显像研究:生理参数的正常范围及其随年龄和性别的变化的可重复性。
J Nucl Med. 1994 Oct;35(10):1612-7.
3
99Tcm-MAG3 renal studies: effective renal plasma flow in patients with spinal cord injuries.
Nucl Med Commun. 1996 Dec;17(12):1068-71.
4
Monitoring of renal function using 99mTc-DMSA and 99mTc-DTPA scintigraphy in patients with spinal cord injury.脊髓损伤患者中使用99m锝-二巯基丁二酸(99mTc-DMSA)和99m锝-二乙三胺五乙酸(99mTc-DTPA)肾动态显像监测肾功能
Rev Esp Med Nucl Imagen Mol. 2012 Nov-Dec;31(6):322-7. doi: 10.1016/j.remn.2011.12.003. Epub 2012 May 6.
5
Background correction in estimating initial renal uptake. Comparison between Tc-99m MAG3 and Tc-99m DTPA.估计初始肾脏摄取时的本底校正。锝-99m 巯基乙酰三甘氨酸与锝-99m 二乙三胺五醋酸的比较。
Clin Nucl Med. 1994 Dec;19(12):1049-54. doi: 10.1097/00003072-199419120-00002.
6
Determination of the normal range of furosemide half-clearance times when using Tc-99m MAG3.使用锝-99m 巯基乙酰三甘氨酸(Tc-99m MAG3)时呋塞米半清除时间正常范围的测定。
Clin Nucl Med. 1994 Oct;19(10):880-2. doi: 10.1097/00003072-199410000-00008.
7
Normal ranges of renal physiological parameters for technetium-99m mercaptoacetyltriglycine and the influence of age and sex using a camera-based method.
Urol Int. 1998;60(1):11-6. doi: 10.1159/000030196.
8
Influence of hydration status in normal subjects: fractional analysis of parameters of Tc-99m DTPA and Tc-99m MAG3 renography.正常受试者水化状态的影响:锝-99m二乙三胺五乙酸和锝-99m巯基乙酰三甘氨酸肾图参数的分数分析
Ann Nucl Med. 2005 Feb;19(1):1-7. doi: 10.1007/BF02986328.
9
A comparison of single plasma sample methods to estimate renal clearance using 99mTc-ethylenedicysteine and 99mTc-mercaptoacetyltriglycine.使用99mTc-乙二半胱氨酸和99mTc-巯基乙酰三甘氨酸通过单份血浆样本方法估算肾清除率的比较。
Clin Physiol Funct Imaging. 2013 Sep;33(5):353-8. doi: 10.1111/cpf.12034. Epub 2013 Mar 18.
10
The accuracy of quantitative parameters in (99m) Tc-MAG3 dynamic renography: a national audit based on virtual image data.(99m)锝-巯基乙酰三甘氨酸动态肾图定量参数的准确性:基于虚拟图像数据的全国性审计。
Clin Physiol Funct Imaging. 2016 Mar;36(2):146-54. doi: 10.1111/cpf.12208. Epub 2014 Oct 28.

引用本文的文献

1
Maximal detrusor pressure can be predicted using technetium-99m-mertcaptoacetyltriglycine renal scintigraphy in the early stages of spinal cord injury.在脊髓损伤的早期阶段,可以使用锝-99m-巯基乙酰三甘氨酸肾闪烁显像术来预测最大逼尿肌压力。
Spinal Cord. 2024 May;62(5):207-213. doi: 10.1038/s41393-024-00967-w. Epub 2024 Mar 7.
2
Urologic surveillance of persons with spinal cord injuries - a scoping review.脊髓损伤患者的泌尿外科监测——一项范围综述
Spinal Cord. 2024 Mar;62(3):91-98. doi: 10.1038/s41393-023-00955-6. Epub 2024 Jan 5.