Suppr超能文献

最佳兼容透析系统的评估:生物电阻抗的可行应用

Assessment of the best compatible dialysis system: feasible application for bioelectrical impedance.

作者信息

Bazzato G, Scanferla F

机构信息

Department of Nephrology and Dialysis, Ospedale Umberto I, Venezia-Mestre, Italy.

出版信息

Int J Artif Organs. 1995 Nov;18(11):712-5.

PMID:8964633
Abstract

Since the introduction of hemodialysis procedure several attempts have been made to elucidate the material tissue interaction in order to evaluate the behaviour of immunosystem cellular and humoral responses to the material of patients on renal replacement therapy. Biochemical and sierological parameters have been considered as method for assessment of the best compatible dialysis. Nevertheless blood tests don't probably reflect the most important symptoms of clinical relevance. Thus we have applied bioelectrical impedance to assess the whole procedure/patient system. Resistance (R) changes during hemodialysis resulted strictly inversely correlated to the body weight variations during HD session (R < 0.96). Reactance (Xc) has also shown a progressive increase associated with an increment of phase angle, while Xc during clinical events such as hypotension, vomiting or cramps showed some transient falls. Also nutritional status and clinical well-being manifested a close relationship with bioelectrical parameters. It is therefore our feeling that BIA monitoring will provide a feasible tool to assess dialysis adequacy, of which biocompatibility represent a crucial aspect.

摘要

自从引入血液透析程序以来,人们进行了多次尝试以阐明材料与组织的相互作用,以便评估接受肾脏替代治疗患者的免疫系统对材料的细胞和体液反应行为。生化和血清学参数已被视为评估最佳相容性透析的方法。然而,血液检测可能无法反映具有临床相关性的最重要症状。因此,我们应用生物电阻抗来评估整个程序/患者系统。血液透析期间的电阻(R)变化与血液透析过程中的体重变化严格呈负相关(R < 0.96)。电抗(Xc)也显示出与相角增加相关的逐渐增加,而在诸如低血压、呕吐或痉挛等临床事件期间Xc显示出一些短暂下降。营养状况和临床健康状况也与生物电参数密切相关。因此,我们认为生物电阻抗分析监测将提供一种可行的工具来评估透析充分性,其中生物相容性是一个关键方面。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验