Borisevich I V, Mikhaĭlov V V, Potryvaeva N V, Malinkin Iu N, Kirillov A P, Krasnianskiĭ V P, Markov V I, Makhlaĭ A A, Lebedinskaia E V
Vopr Virusol. 1996 Sep-Oct;41(5):232-4.
An enzyme immunoassay system has been developed for the detection of Ebola virus antigen. It permits a highly accurate and sensitive rapid detection of the antigen. Optimal dilutions of specific immunoglobulin (1:500, corresponding to protein concentration of 50 micrograms/ml) and conjugate were found. The resolving capacity of the new test system is 1.9 x 10(-7) g protein.
已开发出一种用于检测埃博拉病毒抗原的酶免疫分析系统。它能够高度准确且灵敏地快速检测该抗原。找到了特异性免疫球蛋白(1:500,对应蛋白质浓度为50微克/毫升)和共轭物的最佳稀释度。新测试系统的分辨能力为1.9×10⁻⁷克蛋白质。