Intracoronary ultrasound before coronary interventions: a prospective comparison of two different catheters.

作者信息

Alfonso F, Goicolea J, Perez-Vizcayno M J, Hernandez R, Segovia J, Fernandez-Ortiz A, Bañuelos C, Macaya C

机构信息

Cardiopulmonary Department, Hospital Universitario San Carlos, Madrid, Spain.

出版信息

Cathet Cardiovasc Diagn. 1997 Jan;40(1):33-9. doi: 10.1002/(sici)1097-0304(199701)40:1<33::aid-ccd7>3.0.co;2-c.

Abstract

Intravascular ultrasound (IVUS) provides unique information about the coronary arterial wall that can be used to guide transcatheter therapy. In this prospective study, two different IVUS systems were compared with respect to feasibility of imaging before intervention and angiographic changes induced by the simple advancement of the catheter across the lesion. Eighty-five patients (mean age 59 +/- 10 yr, 11 female) were studied with IVUS before intervention. In 34 patients, a 4.8 F (1.6-mm) IVUS catheter was used (Group I), whereas in the remaining 51 patients, a 3.5 F (1.2-mm) IVUS catheter was used (Group II). Quantitative angiography was performed before and after the IVUS study to determine potential changes in lumen diameter. Clinical and angiographic characteristics were similar in the two groups. A successful IVUS interrogation of the target lesion was obtained more frequently in Group II (45/51 (88%) vs. 19/34 (56%) patients, P < 0.01). After the IVUS study, a change in minimal lumen diameter was seen in Group I (baseline 0.84 +/- 0.2 vs. final 1.17 +/- 0.2 mm, P < 0.001) and Group II patients (baseline 0.80 +/- 0.3 vs. final 1.03 +/- 0.4 mm, P < 0.01). In the 64 lesions successfully crossed, the absolute gain in lumen diameter was significantly higher in Group I (0.40 +/- 0.2 vs. 0.23 +/- 0.2 mm, P < 0.05). In addition, an inverse correlation was found between baseline minimal lumen diameter and the absolute lumen gain induced by the IVUS study in Group I (r = -0.47, P < 0.05) but not in Group II patients (r = -0.16, NS). Neither angiographic nor echogenic lesion characteristics were associated with the change in lumen diameter. When multivariate analysis was applied, catheter size was the only independent predictor of lumen gain induced by IVUS after adjustment. Thus, the advancement of IVUS catheters across severe coronary lesions induces significant angiographic changes consistent with plaque remodeling and a Dotter effect. The use of smaller catheters not only allows a higher number of lesions to be studied before intervention, but also lessens the mechanical disruption of the plaque, yielding a more accurate and veracious picture of baseline plaque characteristics.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验