Suppr超能文献

健康受试者中用碘-123-IBF单光子发射计算机断层显像进行多巴胺D2受体结合的简化定量及可重复性研究

Simplified quantification and reproducibility studies of dopamine D2-receptor binding with iodine-123-IBF SPECT in healthy subjects.

作者信息

Ichise M, Ballinger J R, Vines D, Tsai S, Kung H F

机构信息

Department of Nuclear Medicine, Mount Sinai Hospital, Toronto, Ontario, Canada.

出版信息

J Nucl Med. 1997 Jan;38(1):31-7.

PMID:8998145
Abstract

UNLABELLED

The purpose of this study was to assess the feasibility of a simplified SPECT scan protocol to quantify D2-receptor binding using [123I]iodobenzofuran (IBF) and to evaluate reproducibility of quantitative IBF-SPECT imaging without blood data.

METHODS

Twenty healthy volunteers participated in the study, six had test/retest studies separated by 1 wk. Scans were acquired every 5 min for 180 min using a triple-headed SPECT camera after a bolus injection of IBF (292 MBq). The receptor parameter was determined by using our previously proposed variation of graphical analysis that derives the distribution volume ratio (Rv = V3/V2) from multiple scan data without blood data. Rv' was determined from three 20-min scan data obtained at 0-20, 50-70 and 160-180 min postinjection and compared with Rv as determined from scans obtained at 0-180 min.

RESULTS

The mean Rv' (2.93 +/- 0.59) underestimated the mean Rv (3.10 +/- 0.50) by 5%. The mean variability (mean percent absolute difference) between Rv' and Rv was low (10%) with excellent reliability (intraclass correlation coefficient, p = 0.90). The relationship between Rv' and Rv was linear (r = 0.95, p < 10(-5)). The mean test/retest Rv and mean test/retest Rv' were (3.19 +/- 0.70/3.18 +/- 0.80) and (3.16 +/- 0.81/3.01 +/- 0.94), respectively, and these measures were not significantly different between test/retest studies. The mean test/retest variability of Rv was low (5%) with excellent reliability (p = 0.98). In addition, the mean test/retest variability of Rv' was low (10%) with excellent reliability (p = 0.94).

CONCLUSION

Three short (20 min) IBF-SPECT scans allowing for rest periods between scans permit reliable measurements of the dopamine D2-receptor parameter V3/V2. Quantitative IBF-SPECT imaging without blood data is reliable and reproducible.

摘要

未标注

本研究的目的是评估使用[123I]碘苯并呋喃(IBF)的简化SPECT扫描方案来量化D2受体结合的可行性,并评估无血液数据时定量IBF-SPECT成像的可重复性。

方法

20名健康志愿者参与了本研究,其中6人进行了间隔1周的测试/复测研究。在静脉注射IBF(292MBq)后,使用三头SPECT相机每5分钟采集一次扫描图像,共采集180分钟。受体参数通过使用我们之前提出的图形分析变体来确定,该变体从多个无血液数据的扫描数据中得出分布容积比(Rv = V3/V2)。Rv'由注射后0 - 20、50 - 70和160 - 180分钟获得的三个20分钟扫描数据确定,并与0 - 180分钟扫描获得的Rv进行比较。

结果

Rv'的平均值(2.93±0.59)比Rv的平均值(3.10±0.50)低5%。Rv'与Rv之间的平均变异性(平均绝对差异百分比)较低(10%),可靠性极佳(组内相关系数,p = 0.90)。Rv'与Rv之间的关系呈线性(r = 0.95,p < 10(-5))。测试/复测的Rv平均值和测试/复测的Rv'平均值分别为(3.19±0.70/3.18±0.80)和(3.16±0.81/3.01±0.94),在测试/复测研究中这些测量值无显著差异。Rv的测试/复测平均变异性较低(5%),可靠性极佳(p = 0.98)。此外,Rv'的测试/复测平均变异性较低(10%),可靠性极佳(p = 0.94)。

结论

三次短时间(20分钟)的IBF-SPECT扫描,扫描之间有休息时间,允许可靠测量多巴胺D2受体参数V3/V2。无血液数据的定量IBF-SPECT成像是可靠且可重复的。