Abstract

Enhancement in separation of gangliosides on silica gel precoated high-performance TLC plates has been obtained by automated multiple development chromatography. A less polar mixture of the standard solvent chloroform-methanol-20 mM aqueous CaCl2 (120:85:20, v/v) was used. Lowering the water content achieved separation of two complex monosialoganglioside fractions, isolated from murine YAC 1 T lymphoma and MDAY-D2 lymphoreticular cells. Three-fold chromatography in the solvent chloroform-methanol-20 mM aqueous CaCl2 (120:85:14, v/v) resulted in TLC separation of GM1b-type gangliosides, substituted with C24 and C16 fatty acids and with Neu5Ac and Neu5Gc as well, which could not be achieved by unidirectional standard chromatography. Compared to conventional single chromatography, the technique described allows high-resolution separation of extremely heterogenous ganglioside mixtures and offers a convenient tool for both analytical and preparative TLC.

摘要

通过自动多次展开色谱法,已实现硅胶预涂高效薄层色谱板上神经节苷脂分离的增强。使用了标准溶剂氯仿 - 甲醇 - 20 mM 氯化钙水溶液(120:85:20,v/v)的极性较小的混合物。降低水含量实现了从鼠 YAC 1 T 淋巴瘤和 MDAY - D2 淋巴网状细胞中分离出的两种复杂单唾液酸神经节苷脂组分的分离。在氯仿 - 甲醇 - 20 mM 氯化钙水溶液(120:85:14,v/v)中进行三次展开色谱,实现了 GM1b 型神经节苷脂的薄层色谱分离,这些神经节苷脂被 C24 和 C16 脂肪酸取代,并且还含有 Neu5Ac 和 Neu5Gc,而单向标准色谱法无法实现这种分离。与传统的单次色谱法相比,所述技术能够对极其异质的神经节苷脂混合物进行高分辨率分离,并为分析型和制备型薄层色谱提供了一种便捷工具。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验