Progress towards an alanine/ESR therapy level reference dosimetry service at NPL.

作者信息

Sharpe P H, Rajendran K, Sephton J P

机构信息

National Physical Laboratory, Teddington, Middlesex, U.K.

出版信息

Appl Radiat Isot. 1996 Nov-Dec;47(11-12):1171-5. doi: 10.1016/s0969-8043(96)00174-1.

Abstract

This paper describes work being carried out at the National Physical Laboratory towards the establishment of an alanine reference dosimetry service for radiotherapy applications. A precision fused quartz holder has been constructed to allow precise positioning of alanine dosimeters in the ESR cavity. A novel method of signal analysis based on spectrum fitting has been developed to minimize the effect of baseline distortions. Data are also presented on the relative response of alanine to 60Co gamma rays and high energy photons (4-12 MeV).