Lanz M, Thormann W
Department of Clinical Pharmacology, University of Bern, Switzerland.
Electrophoresis. 1996 Dec;17(12):1945-9. doi: 10.1002/elps.1150171223.
Using capillary zone electrophoresis with a phosphate buffer at pH 3, containing 4.3 mM hydroxypropyl-beta-cyclodextrin as chiral selector, the simultaneous separation of the enantiomers of methadone and its primary metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), is reported. After solid-phase extraction and analysis of the reconstituted extracts in a 60 cm fused-silica capillary of 50 microns ID within about 25 min, the mean S/R enantiomeric ratio of methadone in the urines of eight patients undergoing methadone therapy is shown to be 0.653 (range: 0.502-0.842). The mean enantiomeric ratio for the metabolite is 0.630 (range: 0.517-0.729). These data document the stereoselectivity of the methadone metabolism. Finally, the EDDP/ methadone ratio is shown to vary between 0.357 and 2.917 with a mean value of 1.731. The capillary electrophoretic assay described is simple, inexpensive and neither requires any sample derivatization, nor large amounts of organic solvents or expensive separation columns.
采用毛细管区带电泳法,以pH 3的磷酸盐缓冲液为介质,其中含有4.3 mM羟丙基-β-环糊精作为手性选择剂,实现了美沙酮及其主要代谢物2-亚乙基-1,5-二甲基-3,3-二苯基吡咯烷(EDDP)对映体的同时分离。在经过固相萃取并在一根内径50微米、长60厘米的熔融石英毛细管中对复溶提取物进行分析后,约25分钟内完成检测,结果显示,8名接受美沙酮治疗患者尿液中美沙酮的平均S/R对映体比例为0.653(范围:0.502 - 0.842)。该代谢物的平均对映体比例为0.630(范围:0.517 - 0.729)。这些数据证明了美沙酮代谢的立体选择性。最后,EDDP/美沙酮比例在0.357至2.917之间变化,平均值为1.731。所描述的毛细管电泳分析方法简单、成本低且既不需要任何样品衍生化,也不需要大量有机溶剂或昂贵的分离柱。