Bauer G, Kinzl L
Abteilung für Unfallchirurgie, Hand- und Wiederherstellungschirurgie, Universität Ulm.
Chirurg. 1996 Nov;67(11):1129-34. doi: 10.1007/s001040050114.
Open reduction and internal fixation of intraarticular calcaneus fractures have been increasingly emphasized in recent years. Operation of most of these fractures is via an extended lateral approach. Different implants are used to stabilize the often complex fractures. We have developed a low contact plate that is specially designed for calcaneal fractures. Because the design is based on the anatomy of the calcaneus, all types of fractures can be treated. The plate has a large number of holes to accommodate screw fixation. Our results in 36 cases were comparable to those of other series using open reduction and internal fixation with plates and the demands on the plate were fulfilled.
近年来,关节内跟骨骨折的切开复位内固定术越来越受到重视。这些骨折大多通过延长外侧入路进行手术。使用不同的植入物来稳定通常较为复杂的骨折。我们研发了一种专门为跟骨骨折设计的低接触钢板。由于该设计基于跟骨的解剖结构,所有类型的骨折都能得到治疗。该钢板有大量的孔以适应螺钉固定。我们36例病例的结果与其他使用钢板切开复位内固定术系列的结果相当,并且满足了对钢板的要求。