Suppr超能文献

人类晶状体前囊膜生物力学特性与年龄的关系

Biomechanical characteristics of the human anterior lens capsule in relation to age.

作者信息

Krag S, Olsen T, Andreassen T T

机构信息

Department of Ophthalmology, Aarhus University Hospital, Denmark.

出版信息

Invest Ophthalmol Vis Sci. 1997 Feb;38(2):357-63.

PMID:9040468
Abstract

PURPOSE

The purpose of the study was to investigate the influence of age on the biomechanical properties of the human anterior lens capsule.

METHODS

The material comprised 67 lens capsules obtained from human donors ranging in age from 7 months to 98 years. Test specimens were prepared from the anterior lens capsule as tissue rings by means of excimer laser technique using a metal ring (mask) to shape the laser output (outer diameter = 3.2 mm, width = 100 microns). Capsular thickness was measured under microscope as the difference in focus between microspherules placed on the outer and inner surfaces of the capsule. The rings were slipped over two pins connected to a motorized micropositioner and a force transducer, respectively, and stretched at constant speed until rupture, with continuous recording of load and elongation.

RESULTS

Capsular thickness was associated significantly with age of the donors and increased gradually (1.2% per year) until age 75, after which a slight decrease was observed. The elastic response curves showed a high degree of nonlinearity and were influenced markedly by age. Ultimate strain decreased 0.5% per year (range, 108% to 40%). Ultimate tensile strength decreased 1% per year (range, 17.5 N/mm2 to 1.5 N/mm2), and ultimate elastic stiffness (tangent modulus) decreased 0.9% per year (range, 44.8 N/mm2 to 4.4 N/mm2), whereas elastic stiffness corresponding to a specific strain level (30%) increased until age 35, after which a slight decrease was observed.

CONCLUSIONS

Aging of the human anterior lens capsule is associated with a progressive loss of mechanical strength. The young capsule is strong, tough, and highly extensible, whereas the older, thicker capsule is less extensible and much more brittle, and it has a markedly reduced breaking strength.

摘要

目的

本研究旨在探讨年龄对人晶状体前囊生物力学特性的影响。

方法

材料包括从7个月至98岁的人类供体获取的67个晶状体囊。通过准分子激光技术,使用金属环(掩膜)对激光输出进行塑形(外径 = 3.2毫米,宽度 = 100微米),从前囊制备测试标本作为组织环。在显微镜下测量囊膜厚度,即放置在囊膜外表面和内表面的微球焦点差异。将环套在分别连接到电动微定位器和力传感器的两根销上,并以恒定速度拉伸直至破裂,同时连续记录负荷和伸长情况。

结果

囊膜厚度与供体年龄显著相关,在75岁之前逐渐增加(每年增加1.2%),之后略有下降。弹性响应曲线显示出高度非线性,且受年龄显著影响。极限应变每年下降0.5%(范围为108%至40%)。极限拉伸强度每年下降1%(范围为17.5牛/平方毫米至1.5牛/平方毫米),极限弹性刚度(切线模量)每年下降0.9%(范围为44.8牛/平方毫米至4.4牛/平方毫米),而对应特定应变水平(30%)的弹性刚度在35岁之前增加,之后略有下降。

结论

人晶状体前囊的老化与机械强度的逐渐丧失有关。年轻的囊膜坚固、坚韧且具有高度可扩展性,而年老、较厚的囊膜可扩展性较差且更脆,其断裂强度明显降低。