Effect of varying atrial sensitivity, AV interval, and detection algorithm on automatic mode switching.

作者信息

Palma E C, Kedarnath V, Vankawalla V, Andrews C A, Hanson S, Furman S, Gross J N

机构信息

Pacemaker Center, Montefiore Medical Center, Bronx, New York 10467, USA.

出版信息

Pacing Clin Electrophysiol. 1996 Nov;19(11 Pt 2):1735-9.

PMID:9045215
Abstract

UNLABELLED

Automatic mode switching (AMS) is absolutely dependent on atrial tachyarrhythmia detection. The effects of programming several features that could influence tachyarrhythmia detection were assessed in 18 patients (six women; mean age 64 years) with pacemakers having AMS capability. The atrial electrogram amplitude in sinus rhythm at implant (SR-EGM), last measured atrial sensing threshold prior to tachycardia (A-SENS), and atrial sensing threshold for effective AMS during atrial tachyarrhythmia (AMS-SENS) were obtained. Additionally, ten patients had AV intervals increased from 60 to 200 ms, while seven patients had detection algorithms made more stringent from 5 beats at 150 beats/min to 11 beats at 200 beats/min to assess their effects on AMS efficacy.

RESULTS

Sensitivities:Mean SR-EGM = 3.55 mV; mean A-SENS = 2.06 mV; and mean AMS-SENS = 1.46 mV. Fourteen patients developed atrial fibrillation and four atrial flutter. Thirteen of 14 patients who developed atrial fibrillation sensed adequately at > or = 1.0 mV in normal sinus rhythm (NSR), but only six patients had effective AMS at these settings in atrial fibrillation. Three of four patients who developed atrial flutter had effective AMS at > or = 2.0 mV. AV Interval:AMS was effective in eight of ten patients at AV intervals up to 200 ms. One patient lost AMS at an AV interval of 120 ms. Algorithm: In two of seven patients, AMS was not effective if the detection algorithm was more stringent than five beats at 150 beats/min.

CONCLUSIONS

(1) In atrial fibrillation, effective AMS requires more sensitive atrial settings than in NSR; (2) AV intervals as short as 120 ms can interfere with AMS function; and (3) More stringent detection algorithms may be inappropriate for effective AMS function.

摘要

相似文献

1
Effect of varying atrial sensitivity, AV interval, and detection algorithm on automatic mode switching.
Pacing Clin Electrophysiol. 1996 Nov;19(11 Pt 2):1735-9.
2
[Mode-switching algorithms: programming and usefulness].[模式切换算法:编程与实用性]
Herz. 2001 Feb;26(1):2-17. doi: 10.1007/pl00002003.
3
Reliability of a new algorithm for automatic mode switching from DDDR to DDIR pacing mode in sinus node disease patients with chronotropic incompetence and recurrent paroxysmal atrial fibrillation.一种用于变时功能不全且反复阵发性心房颤动的窦房结疾病患者从DDDR起搏模式自动切换至DDIR起搏模式的新算法的可靠性
Pacing Clin Electrophysiol. 1996 Nov;19(11 Pt 2):1719-23. doi: 10.1111/j.1540-8159.1996.tb03213.x.
4
Is automatic mode switching effective for atrial arrhythmias occurring at different rates? A study of the efficacy of automatic mode and rate switching to simulated atrial arrhythmias by chest wall stimulation.
Pacing Clin Electrophysiol. 2000 May;23(5):824-31. doi: 10.1111/j.1540-8159.2000.tb00850.x.
5
Automatic mode switching of implantable pacemakers: I. Principles of instrumentation, clinical, and hemodynamic considerations.植入式起搏器的自动模式切换:I. 仪器原理、临床及血流动力学考量
Pacing Clin Electrophysiol. 2002 Jun;25(6):967-83. doi: 10.1046/j.1460-9592.2002.00967.x.
6
A comparative study on the behavior of three different automatic mode switching dual chamber pacemakers to intracardiac recordings of clinical atrial fibrillation.
Pacing Clin Electrophysiol. 2000 Dec;23(12):2086-96. doi: 10.1111/j.1540-8159.2000.tb00781.x.
7
Programmed atrial sensitivity: a critical determinant in atrial fibrillation detection and optimal automatic mode switching.程控心房感知:心房颤动检测及最佳自动模式转换的关键决定因素。
Pacing Clin Electrophysiol. 1998 Nov;21(11 Pt 2):2214-9. doi: 10.1111/j.1540-8159.1998.tb01155.x.
8
Initial experience with a new algorithm for automatic mode switching from DDDR to DDIR mode.一种用于从DDDR模式自动切换到DDIR模式的新算法的初步经验。
Pacing Clin Electrophysiol. 1994 Nov;17(11 Pt 2):1908-12. doi: 10.1111/j.1540-8159.1994.tb03772.x.
9
[A preliminary study on the role of anti-atrial fibrillation pacemaker in the prevention of atrial tachyarrhythmia].[抗心房颤动起搏器在预防房性快速性心律失常中作用的初步研究]
Zhonghua Xin Xue Guan Bing Za Zhi. 2005 Sep;33(9):824-6.
10
Amplitude based beat detection for atrial fibrillation in pacemaker.基于幅度的起搏器心房颤动搏动检测
Annu Int Conf IEEE Eng Med Biol Soc. 2016 Aug;2016:2757-2759. doi: 10.1109/EMBC.2016.7591301.