Recent progress in engineering the Pittsburgh intravenous membrane oxygenator.

作者信息

Federspiel W J, Hewitt T, Hout M S, Walters F R, Lund L W, Sawzik P J, Reeder G, Borovetz H S, Hattler B G

机构信息

Department of Surgery, University of Pittsburgh, Pennsylvania 15219, USA.

出版信息

ASAIO J. 1996 Sep-Oct;42(5):M435-42. doi: 10.1097/00002480-199609000-00026.

Abstract

The University of Pittsburgh intravenous membrane oxygenator (IMO) is undergoing additional engineering development and characterization. The focus of these efforts is an IMO device that can supply as much as one-half basal O2 consumption and CO2 elimination rates while residing within the inferior and superior vena cavae after peripheral venous insertion. The current IMO design consists of a bundle of hollow fiber membranes potted to manifolds at each end, with an intra-aortic type balloon integrally situated within the fiber bundle. Pulsation of the balloon using helium gas and a balloon pump console promotes fluid and fiber motion and enhances gas exchange. During the past year, more than 15 IMO prototypes have been fabricated and extensively bench tested to characterize O2 gas exchange capacity, balloon inflation/deflation over relevant frequency ranges, and the pneumatics of the sweep gas pathway through the device. The testing has led to several engineering changes, including redesign of the helium and sweep gas pathways within the IMO device. As a result, the maximum rate of balloon pulsation has increased substantially above the previous 70 bpm to 160 bpm, and the vacuum pressure required for sufficient sweep gas flow has been reduced. The recent IMO prototypes have demonstrated an O2 exchange capacity of as much as 90 ml/min/m2 in water, which appears within 70% of our design goal when extrapolated to scaled up devices in blood.

摘要

相似文献

1
Recent progress in engineering the Pittsburgh intravenous membrane oxygenator.
ASAIO J. 1996 Sep-Oct;42(5):M435-42. doi: 10.1097/00002480-199609000-00026.
2
Acute in vivo studies of the Pittsburgh intravenous membrane oxygenator.
ASAIO J. 1996 Sep-Oct;42(5):M609-15. doi: 10.1097/00002480-199609000-00060.
3
Ex vivo testing of the intravenous membrane oxygenator.
ASAIO J. 2000 May-Jun;46(3):261-7. doi: 10.1097/00002480-200005000-00004.
4
A mathematical model of gas exchange in an intravenous membrane oxygenator.
Ann Biomed Eng. 1998 Jan-Feb;26(1):166-78. doi: 10.1114/1.53.
5
Current progress in the development of an intravenous membrane oxygenator.
ASAIO J. 1993 Jul-Sep;39(3):M461-5. doi: 10.1097/00002480-199307000-00062.
7
Vibration analysis of vessel wall motion with intra vena caval balloon pumping.
ASAIO J. 1994 Jul-Sep;40(3):M740-2. doi: 10.1097/00002480-199407000-00097.
8
Improved gas exchange performance of the intravascular oxygenator by active blood mixing.
ASAIO J. 1994 Jul-Sep;40(3):M527-32. doi: 10.1097/00002480-199407000-00056.
10
Development of a balloon volume sensor for pulsating balloon catheters.
ASAIO J. 2004 May-Jun;50(3):225-33. doi: 10.1097/01.mat.0000123635.20778.52.

引用本文的文献

1
Intravascular Gas Exchange: Physiology, Literature Review, and Current Efforts.
Respir Care. 2022 Apr;67(4):480-493. doi: 10.4187/respcare.09288.
2
Evaluation of fiber bundle rotation for enhancing gas exchange in a respiratory assist catheter.
ASAIO J. 2007 May-Jun;53(3):368-73. doi: 10.1097/MAT.0b013e318031af3b.
3
Design of an intravenous oxygenator.
J Artif Organs. 2006;9(1):34-41. doi: 10.1007/s10047-005-0312-1.
4
Flow visualization study of a pulsating respiratory assist catheter.
ASAIO J. 2005 Nov-Dec;51(6):673-80. doi: 10.1097/01.mat.0000187393.79866.9c.
5
Acute in vivo testing of a respiratory assist catheter: implants in calves versus sheep.
ASAIO J. 2003 Jul-Aug;49(4):370-7. doi: 10.1097/01.mat.0000074991.94234.b6.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验