Kim J W, Kikkawa D O, Lemke B N
Department of Ophthalmology, University of California, San Diego, La Jolla, USA.
Ophthalmic Plast Reconstr Surg. 1997 Mar;13(1):36-9. doi: 10.1097/00002341-199703000-00007.
The use of hard palate mucosal grafts (HPG) in eyelid surgery is becoming increasingly popular. We present two palatal donor site complications that have not been previously reported. The first is an oro-nasal fistula discovered 1 week following surgery. The second is oral candidiasis, which compromised healing of the palatal donor site. With appropriate treatment, both complications resolved shortly after surgery. Careful preoperative evaluation and postoperative follow-up is recommended to recognize and manage these complications.