Suppr超能文献

Comparison of platelet loss during leukocyte reduction at 4, 24, and 48 hours postcollection using a Closed System Apheresis Kit with Integral filter.

作者信息

Jin Y S, Mintz P D

机构信息

Blood Bank Service, University of Virginia Health Sciences Center, Charlottesville 22908, USA.

出版信息

J Clin Apher. 1997;12(1):14-7. doi: 10.1002/(sici)1098-1101(1997)12:1<14::aid-jca4>3.0.co;2-d.

Abstract

Prestorage leukocyte reduction of platelet concentrates may reduce adverse effects of transfusion while affording better quality control. Platelets and leukocytes may undergo activation during storage, which could affect the performance of leukocyte reduction filters. The purpose of this study was to evaluate the efficiency of leukocyte reduction and concomitant platelet loss with a new apheresis kit with an integral leukocyte reduction filter. Twelve donors underwent plateletpheresis on three occasions using the CS-3000 PLUS Blood Cell Separator with the Access Management System and the Access Closed System Apheresis Kit with Integral Sepacell Leukocyte Reduction Filter and Double Return Line Needle (Baxter-Fenwal Division, Deerfield, IL). Of the three products from each donor, one each was filtered at 4, 24, and 48 hours after completion of the plateletpheresis. Mean prefiltration platelet count was 4.43 x 10(11) and mean postfiltration platelet count was 3.56 x 10(11). Mean platelet recovery at 4, 24, and 48 hours filtration was 75%, 83%, and 84%, respectively. Analysis of variance (ANOVA) demonstrated that platelet recovery with filtration at four hours was significantly less than with filtration at 24 hours (P = 0.0236) and filtration at 48 hours (P = 0.0122). Platelet recovery with filtration at 24 hours did not differ significantly from filtration at 48 hours (P = 0.7684). Mean prefiltration WBC count was 0.93 x 10(6) and mean postfiltration WBC count was 0.12 x 10(6). Efficiency of leukocyte reduction was not significantly related to when filtration was performed. There was no significant variation from donor in platelet recovery or in leukocyte reduction efficiency. This method of prestorage leukocyte reduction demonstrated slightly but statistically significantly better platelet recovery with filtration at 24 or 48 hours after platelet collection compared to four hours. All filtration times provided acceptable platelet yields with very low residual WBC.

摘要

相似文献

3
Providing leukocyte-reduced platelets using the CS-3000 PLUS.
J Clin Apher. 1996;11(1):27-9. doi: 10.1002/(SICI)1098-1101(1996)11:1<27::AID-JCA6>3.0.CO;2-D.
4
Improved removal of white cells with minimal platelet loss by filtration of apheresis platelets during collection.
Transfusion. 1999 Jan;39(1):74-82. doi: 10.1046/j.1537-2995.1999.39199116898.x.
9
[The effect of leukocyte depletion by filtration on the quality of apheresis platelets].
Zhongguo Shi Yan Xue Ye Xue Za Zhi. 2009 Aug;17(4):1067-70.
10
In vitro and in vivo effects of prestorage filtration of apheresis platelets.
Transfusion. 1995 Feb;35(2):125-30. doi: 10.1046/j.1537-2995.1995.35295125734.x.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验