Suppr超能文献

通过碘量法和气液色谱法评估不同多合一混合袋中静脉脂质乳剂的体外氧化。

In vitro oxidation of i.v. lipid emulsions in different all-in-one admixture bags assessed by an iodometric assay and gas-liquid chromatography.

作者信息

Steger P J, Mühlebach S F

机构信息

Department of Pharmacy, Kantonsspital Aarau, Switzerland.

出版信息

Nutrition. 1997 Feb;13(2):133-40. doi: 10.1016/s0899-9007(96)00387-5.

Abstract

Polyunsaturated fatty acids (FAs) of intravenous (IV) lipid emulsions can peroxidize to potentially harmful lipid hydroperoxides. In order to assess in vitro peroxidation of IV fat emulsions in all-in-one (AIO) admixture bags, an iodometric titration to determine lipid hydroperoxide content expressed by the peroxide value (PV) and a gas-liquid chromatographic (GLC) assay to determine changes of the FA pattern were established. A long-chain triglyceride (LCT) and medium-chain triglyceride-LCT emulsion were compared for the PV and the pH during storage at room temperature and daylight in AIO bags made of ethylvinylacetate (EVA) and polypropylene:polyamide 7:3 (V90). In contrast to storage in glass bottles, significant peroxidation was detected in both emulsions with 0.5-3.4 mmol peroxides/L after 28 d (150 times the control PV). A pH drop of at least 0.3 (EVA) and 1.2 (V90) units was measured. Initial PVs and peroxidation kinetics of the emulsions were different; V90 material showed better barrier properties against oxygen. PV was increased by higher temperature and light exposure. The FA pattern of an LCT emulsion with a PV > 6 (storage: 40 degrees C in a dark room for 28 d in AIO bags) assayed by GLC remained unchanged. The iodometric peroxide and the GLC assay were reproducible and easy to handle. Only the iodometric method was sensitive enough to detect peroxidation effects (detection limit: 0.02 mmol peroxides/L). IV fat emulsions can be checked for lipid hydroperoxide content with the rapid iodometric assay to guarantee optimal quality of IV lipids used for AIO admixtures. To prevent peroxidation, lipids in AIO bags should be stored light-protected in a refrigerator an oxygen-tight overwrap is mandatory for extended periods.

摘要

静脉注射(IV)脂肪乳剂中的多不饱和脂肪酸(FAs)会过氧化生成潜在有害的脂质氢过氧化物。为了评估全合一(AIO)混合袋中IV脂肪乳剂的体外过氧化情况,建立了一种碘量滴定法来测定以过氧化值(PV)表示的脂质氢过氧化物含量,以及一种气液色谱(GLC)分析法来测定脂肪酸模式的变化。比较了长链甘油三酯(LCT)和中链甘油三酯-LCT乳剂在由乙烯-醋酸乙烯酯(EVA)和聚丙烯:聚酰胺7:3(V90)制成的AIO袋中,于室温及日光下储存期间的PV和pH值。与储存在玻璃瓶中不同,两种乳剂在28天后均检测到显著过氧化,过氧化值为0.5 - 3.4 mmol过氧化物/L(是对照PV的150倍)。测得pH值至少下降0.3(EVA)和1.2(V90)个单位。乳剂的初始PV和过氧化动力学不同;V90材料对氧气显示出更好的阻隔性能。PV会因温度升高和光照而增加。通过GLC分析,PV > 6的LCT乳剂(储存条件:在AIO袋中于暗室40℃下储存28天)的脂肪酸模式保持不变。碘量法过氧化物测定和GLC分析具有可重复性且易于操作。只有碘量法灵敏到足以检测过氧化效应(检测限:0.02 mmol过氧化物/L)。可以用快速碘量法检测IV脂肪乳剂中的脂质氢过氧化物含量,以确保用于AIO混合制剂的IV脂质的最佳质量。为防止过氧化,AIO袋中的脂质应避光储存在冰箱中,长时间储存时必须使用密封外包装。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验