Coche G, Izet T, Descombes P, Duchman J C, Sevenet F, Dupas J L, Vanthournout I, Capron J P
Services de Radiologie et Gastroentérologie, Clinique du Mail, Mail Albert-Premier, Amiens.
J Radiol. 1997 Mar;78(3):215-7.
Glutaraldehyde disinfectant solution may be a cause of toxic chemical colitis. We report two cases. Ultrasonic features were studied in one case and mimic colonic ischemia, inflammatory and/or infectious colitis. These findings were colonic wall thickening especially mucosal (hypoechogenicity) and submucosal (hyperechogenicity) layers. This diagnosis should be discussed when one sees a patient with echographic findings of acute left-sided colitis just after uncomplicated colonic endoscopy.