Suppr超能文献

采用5.0毫米缝合及3.5毫米无缝合透明角膜切口的白内障手术后的角膜变化

Corneal changes after cataract surgery with 5.0 mm sutured and 3.5 mm sutureless clear corneal incisions.

作者信息

Holweger R R, Marefat B

机构信息

Northwest Kansas Eye Clinic, Hays 67601, USA.

出版信息

J Cataract Refract Surg. 1997 Apr;23(3):342-6. doi: 10.1016/s0886-3350(97)80177-0.

Abstract

PURPOSE

To study corneal changes after endocapsular phacoemulsification cataract extraction and intraocular lens (IOL) implantation with a 3.5 mm clear corneal sutureless incision or a 5.0 mm clear corneal incision with an absorbable suture.

SETTING

Northwest Kansas Eye Clinic, Hays, Kansas, USA.

METHODS

In a prospective study, 200 eyes were randomly distributed into two groups. Group A comprised 100 eyes that had a silicone IOL inserted through a 3.5 mm sutureless clear corneal incision. Group B comprised 100 eyes that had a 5.0 mm poly(methyl methacrylate) (PMMA) IOL inserted through a 5.0 mm clear corneal incision; one half of the closures used a single radial suture (Group B1), and the other half, an X suture (Group B2). Preoperatively, corneal topography and corneal endothelial cell counts were performed. Six to 8 months postoperatively, they were repeated and evaluated. Differential topography was used to determine the difference between the preoperative and postoperative corneas. During the final postoperative visit, IOL centration was evaluated.

RESULTS

All closures produced only minimal changes in the corneal topographic indices. The postoperative corneas closely resembled the preoperative corneas. Polar K values showed a slight astigmatic shift in all groups. Group B2 was the only one to exhibit a with-the-rule shift. The change in endothelial cell counts was minimal and comparable in all three groups.

CONCLUSION

The small amount of change in the corneal indices, especially in surface regularity, indicates that all corneas were relatively comparable and stable 6 to 9 months postoperatively regardless of the type of incision and closure method.

摘要

目的

研究采用3.5mm透明角膜无缝线切口或5.0mm带可吸收缝线的透明角膜切口进行囊内超声乳化白内障摘除及人工晶状体(IOL)植入术后的角膜变化。

地点

美国堪萨斯州海斯市西北堪萨斯眼科诊所。

方法

在一项前瞻性研究中,200只眼被随机分为两组。A组包括100只通过3.5mm无缝线透明角膜切口植入硅胶IOL的眼。B组包括100只通过5.0mm透明角膜切口植入聚甲基丙烯酸甲酯(PMMA)IOL的眼;一半的切口采用单根放射状缝线闭合(B1组),另一半采用X形缝线闭合(B2组)。术前进行角膜地形图和角膜内皮细胞计数。术后6至8个月,重复进行并评估这些检查。采用差异地形图来确定术前和术后角膜之间的差异。在术后最后一次随访时,评估IOL的中心定位情况。

结果

所有切口闭合方式仅使角膜地形图指数产生极小的变化。术后角膜与术前角膜非常相似。极地K值在所有组中均显示出轻微的散光偏移。B2组是唯一呈现顺规偏移的组。三组中内皮细胞计数的变化均极小且相当。

结论

角膜指数的少量变化,尤其是表面规则性方面的变化,表明无论切口类型和闭合方法如何,所有角膜在术后6至9个月时相对可比且稳定。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验