The H reflex in the S1 spinal nerve has been used in electrodiagnosis of S1 radiculopathy for several years. Direct stimulation of the S1 spinal nerve has provided more complete information about the H reflex pathway by dividing it into its peripheral and central (or spinal) conduction portions. A previous study compared spinal nerve latency with the H reflex latency, demonstrating an abnormal S1 ratio in subjects with S1 radiculopathy, thereby suggesting slowing within the spinal segment of the nerve. No study, however, has established a normal value for the central (spinal) portion of the H reflex. We electrodiagnostically tested 20 subjects with normal clinical neurologic and musculoskeletal examinations to define a normal sample of the central loop of the H reflex in the S1 spinal nerve. The peak latencies of the M and H reflex responses were measured after a single stimulus to the S1 spinal nerve. The data obtained established 7 +/- 0.3 ms as the normal value for the interpotential latency difference (central loop) of the H reflex in the S1 spinal nerve in healthy subjects. Six patients with clinical and electromyographic evidence of S1 radiculopathy all had central loop latencies of > 8 ms. The normal value of the central loop of the H reflex suggested in this pilot investigation may, therefore, be used to allow for earlier and more accurate diagnosis of an acute S1 radiculopathy.
多年来,S1脊神经的H反射一直用于S1神经根病的电诊断。直接刺激S1脊神经,通过将H反射通路分为外周和中枢(或脊髓)传导部分,提供了关于该通路更完整的信息。先前的一项研究比较了脊神经潜伏期和H反射潜伏期,结果显示S1神经根病患者的S1比值异常,从而提示该神经脊髓节段存在传导减慢。然而,尚无研究确定H反射中枢(脊髓)部分的正常值。我们对20例临床神经学和肌肉骨骼检查正常的受试者进行了电诊断测试,以确定S1脊神经H反射中枢环路的正常样本。对S1脊神经进行单次刺激后,测量M和H反射反应的峰值潜伏期。所获得的数据确定,健康受试者S1脊神经H反射的电位间潜伏期差(中枢环路)的正常值为7±0.3毫秒。6例有S1神经根病临床和肌电图证据的患者,其中枢环路潜伏期均>8毫秒。因此,这项初步研究中提出的H反射中枢环路正常值,可能有助于更早、更准确地诊断急性S1神经根病。