Snook S H, Vaillancourt D R, Ciriello V M, Webster B S
Liberty Mutual Research Center for Safety and Health, Hopkinton, MA 01748, USA.
Am Ind Hyg Assoc J. 1997 Jul;58(7):509-17. doi: 10.1080/15428119791012603.
The purpose of this experiment was to quantify maximum acceptable forces for ulnar deviation motions of the wrist at various repetition rates. Subjects grasped a handle with a power grip and moved it through a 1.40 rad (80 degrees) ulnar deviation wrist motion (similar to a knife cutting task). A psychophysical methodology was used in which the subject adjusted the resistance on the handle and the experiment manipulated or controlled all other variables. Two series of experiments were conducted. Thirteen subjects completed the first series, which investigated repetition rates of 15 and 20 motions per minute. Eleven subjects completed the second series, which investigated 15, 20, and 25 motions per minute. Subjects performed for 7 hours per day, 5 days per week, for 4 weeks in the first series and 5 weeks in the second series. The subjects were instructed to work as if they were on an incentive basis, getting paid for the amount of work they performed. Symptoms were recorded by the subjects during the last 5 minutes of each hour. The results are presented and compared with maximum acceptable forces for wrist flexion and extension.