Gee W, Oller D W, Amundsen D G, Goodreau J J
Arch Surg. 1977 Nov;112(11):1381-8. doi: 10.1001/archsurg.1977.01370110115013.
Patients with asymptomatic carotid bruits require some noninvasive method for detecting which would benefit from angiography and possible prophylactic operative repair of the suspected atherosclerotic lesion. This report describes the use of the ocular pneumoplethysmograph (OPG) in this regard. Data for establishing OPG criteria of significant carotid stenosis were derived from studies in symptomatic patients who had also undergone angiography. In this review, the OPG demonstrated an accuracy of 91.6% in detecting at least a 75% diameter stenosis. The OPG criteria were applied to 116 patients with asymptomatic carotid bruits. Forty two of the 116 patients fulfilled at least one of the four criteria for angiography. In 38 of the 40 patients who underwent angiography, the OPG findings were confirmed, for an accuracy of 95%. Twenty-two patients underwent 27 operations, without morbidity or mortality.
无症状性颈动脉杂音患者需要某种无创方法来检测哪些患者将从血管造影以及对疑似动脉粥样硬化病变进行可能的预防性手术修复中获益。本报告描述了在这方面眼体积描记器(OPG)的应用。确立显著颈动脉狭窄的OPG标准的数据来源于对有症状且也接受了血管造影的患者的研究。在本综述中,OPG在检测至少75%管径狭窄方面显示出91.6%的准确率。OPG标准应用于116例无症状性颈动脉杂音患者。116例患者中有42例满足血管造影的四项标准中的至少一项。在接受血管造影的40例患者中的38例中,OPG检查结果得到证实,准确率为95%。22例患者接受了27次手术,无并发症或死亡。