Held P, Fellner C, Fellner F, Seitz J, Strutz J
Department of Diagnostic Radiology, University of Regensburg, Germany.
Br J Radiol. 1997 May;70(833):465-72. doi: 10.1259/bjr.70.833.9227227.
The aim of this study was to compare contrast enhanced 3D MP-RAGE (magnetization prepared rapid gradient echo), unenhanced 3D MP-RAGE and 3D CISS (constructive interference in steady state) in the evaluation of anatomical detail of the inner ear and facial nerve. 60 persons with no abnormalities and no or non-specific symptoms were examined with MRI. All examinations were performed using a 1.5 T MR unit. The detectability of anatomical details was evaluated by agreement of three radiologists. Statistical evaluation of the results was achieved by the two-tailed Wilcoxon's test. In 86-95% of the cases, 3D CISS resulted in excellent visibility of the basal and second turn and apex of the cochlea, the vestibule and semicircular canals, as well as the nerves within the internal auditory canal. There was a significantly better visualization with CISS than with MP-RAGE. Detectability of the extrameatal facial nerve was best using contrast enhanced 3D MP-RAGE in 91-96% of the cases (labyrinthine segment 96.7%; geniculate ganglion 95%; tympanic segment 91.7%; vertical segment 95%). The detection of the meatal seventh nerve was best using CISS, whilst unenhanced MP-RAGE gave significantly better results than contrast enhanced MP-RAGE. These results suggest that unenhanced and contrast enhanced 3D MP-RAGE and 3D CISS sequences are complementary and not alternative MRI techniques. Both T1 and T2 weighted 3D MR imaging of the temporal bone is of advantage when compared with 2D MR sequences due to improved contrast, geometrical resolution and the possibility of adequate reconstruction of anatomical structures.
本研究的目的是比较对比增强三维磁化准备快速梯度回波序列(MP-RAGE)、非增强三维MP-RAGE序列和三维稳态构成干扰序列(CISS)在评估内耳和面神经解剖细节方面的效果。对60名无异常且无或有非特异性症状的人员进行了MRI检查。所有检查均使用1.5T MR设备进行。由三名放射科医生达成一致意见来评估解剖细节的可检测性。结果采用双尾Wilcoxon检验进行统计学评估。在86%至95%的病例中,三维CISS序列能清晰显示耳蜗底圈、第二圈和顶圈、前庭和半规管以及内耳道内的神经。CISS序列的可视化效果明显优于MP-RAGE序列。在91%至96%的病例中,对比增强三维MP-RAGE序列对耳外段面神经的可检测性最佳(迷路段96.7%;膝状神经节95%;鼓室段91.7%;垂直段95%)。CISS序列对耳道内第七神经的检测效果最佳,而非增强MP-RAGE序列的结果明显优于对比增强MP-RAGE序列。这些结果表明,非增强和对比增强三维MP-RAGE序列与三维CISS序列是互补的,而非替代的MRI技术。与二维MR序列相比,颞骨的三维T1加权和T2加权MR成像具有对比度更高、几何分辨率更高以及能够充分重建解剖结构的优势。