Held P, Fellner C, Fellner F, Geissler A, Gmeinwieser J
Klinikum der Universität Regensburg, Institut für Röntgendiagnostik, Germany.
Br J Radiol. 1995 Dec;68(816):1316-24. doi: 10.1259/0007-1285-68-816-1316.
Imaging with three-dimensional (3D) sequences is a frequently used magnetic resonance (MR) technique in the assessment of ear, nose and throat (ENT) tumours near the skull base. Few reports on the contrast behaviour of 3D magnetization prepared rapid gradient echo (MP-RAGE) sequences and their application in ENT tumours exist in the published literature. This paper discusses whether 3D MP-RAGE is an alternative to conventional 3D gradient echo (3D GE) sequences for the diagnostic evaluation of the visceral cranum. Measurements were performed with a Magnetom SP 63 MR system (Siemens) at 1.5 T. 10 healthy volunteers were examined using 3D FLASH sequences with varied flip angles (90 degrees, 70 degrees, 40 degrees, 20 degrees, 10 degrees) and using 3D MP-RAGE to optimize the signal-to-noise ratio (SNR) of muscle, fat and gland tissue. After this optimization 25 patients with ENT tumours near the skull base were examined with 3D FLASH 40 degrees, 3D MP-RAGE 10 degrees (both before and after application of contrast medium) and with 3D FISP 70 degrees (without contrast medium). SNR and contrast-to-noise ratio (CNR) of tumour, inflammatory disease, brain (white and grey matter), compact bone, fat and muscle were calculated. The advantages of 3D MP-RAGE over 3D FLASH 40 degrees include decreased imaging time with decreased motion artifacts and a relatively high contrast between tumour and surrounding tissues. The tissue contrast yielded by the T1/T2* weighted 3D gradient echo sequence FISP with a flip angle of 70 degrees was not as good as that yielded by 3D MP-RAGE with and without contrast together. In conclusion a combination of contrast enhanced and unenhanced 3D MP-RAGE sequences is the technique of choice for the examination of ENT tumours near the base of the skull.
三维(3D)序列成像在评估颅底附近的耳鼻喉(ENT)肿瘤时是一种常用的磁共振(MR)技术。已发表的文献中关于3D磁化准备快速梯度回波(MP-RAGE)序列的对比行为及其在ENT肿瘤中的应用的报道很少。本文讨论3D MP-RAGE是否可替代传统的3D梯度回波(3D GE)序列用于诊断评估面颅。使用1.5 T的Magnetom SP 63 MR系统(西门子)进行测量。对10名健康志愿者使用具有不同翻转角(90度、70度、40度、20度、10度)的3D FLASH序列以及使用3D MP-RAGE来优化肌肉、脂肪和腺体组织的信噪比(SNR)。在此优化之后,对25名患有颅底附近ENT肿瘤的患者使用3D FLASH 40度、3D MP-RAGE 10度(均在注射造影剂前后)以及3D FISP 70度(不注射造影剂)进行检查。计算肿瘤、炎症性疾病、脑(白质和灰质)、致密骨、脂肪和肌肉的SNR和对比噪声比(CNR)。3D MP-RAGE相对于3D FLASH 40度的优势包括成像时间缩短、运动伪影减少以及肿瘤与周围组织之间具有相对较高的对比度。翻转角为70度的T1/T2*加权3D梯度回波序列FISP所产生的组织对比度不如有造影剂和无造影剂的3D MP-RAGE所产生的组织对比度好。总之,对比增强和未增强的3D MP-RAGE序列相结合是检查颅底附近ENT肿瘤的首选技术。