Suppr超能文献

尿液分析试纸条的半自动读取与目视读取

Semi-automated vs. visual reading of urinalysis dipsticks.

作者信息

Peele J D, Gadsden R H, Crews R

出版信息

Clin Chem. 1977 Dec;23(12):2242-6.

PMID:923074
Abstract

Semi-automated reflectance readings of urinalysis dipsticks showed better precision than visual readings in the case of artificially prepared urine samples containing glucose, ketone, and protein. Actual pathological specimens containing glucose, protein, and nitrite also showed that instrumental readings were better than visual. Results of repeated visual readings spread over three different color blocks for certain concentrations of glucose, ketone, and protein, whereas repeated instrumental readings were never spread greater than two color blocks. Subjectivity can be reduced by semi-automated dipstick urinalysis.

摘要

对于含有葡萄糖、酮体和蛋白质的人工制备尿液样本,尿液分析试纸条的半自动反射率读数比目视读数具有更高的精度。含有葡萄糖、蛋白质和亚硝酸盐的实际病理标本也表明,仪器读数优于目视读数。对于某些浓度的葡萄糖、酮体和蛋白质,重复的目视读数分布在三个不同的颜色块上,而重复的仪器读数分布从未超过两个颜色块。半自动试纸条尿液分析可以减少主观性。