Drangova M, Zhu Y, Pelc N J
Richard M. Lucas Center for MR Imaging and Spectroscopy, Department of Radiology, Stanford University, CA 94305, USA.
J Magn Reson Imaging. 1997 Jul-Aug;7(4):664-8. doi: 10.1002/jmri.1880070409.
The reproducibility of myocardial motion trajectories calculated from cine phase-contrast (PC) velocity data is reduced by artifacts due to the inconsistent motion of intracardiac blood. Spatial presaturation reduces these artifacts but requires a longer sequence TR, with a potentially negative effect on trajectory accuracy and reproducibility. We investigated the effect of spatial presaturation on trajectory reproducibility. A mid-ventricular transaxial slice was imaged in five normal volunteers. The same slice was imaged three times each with sequences using spatial presaturation or not. Because the most serious artifacts originate in the heart chambers and propagate in the phase-encoded direction, myocardial regions that were in line with the heart chambers (in the phase-encode direction) had the highest artifact level in the scans without spatial presaturation. The reproducibility of trajectories for regions placed in these areas (the anterior wall, septum and posterior wall in the transaxial scans with phase encoding in the anterior-posterior direction) improved by a factor of two when presaturation was used (P < .001). In areas that were not in line with the heart chambers (eg, the anterior aspect of the lateral wall in the transaxial scans), the effect of presaturation was not significant. These results correlate well with the measured reduction in artifact level. The reproducibility of myocardial motion trajectories over large areas of the heart is improved to approximately 1 mm when presaturation is used. Therefore, use of presaturation is recommended for myocardial motion studies using cine PC velocity data.
由于心腔内血液运动不一致所产生的伪影会降低从电影相位对比(PC)速度数据计算得到的心肌运动轨迹的可重复性。空间预饱和可减少这些伪影,但需要更长的序列重复时间(TR),这可能会对轨迹准确性和可重复性产生负面影响。我们研究了空间预饱和对轨迹可重复性的影响。对五名正常志愿者的心室中部横断面进行成像。使用或不使用空间预饱和的序列对同一横断面各成像三次。由于最严重的伪影起源于心腔并沿相位编码方向传播,在没有空间预饱和的扫描中,与心腔对齐(在相位编码方向上)的心肌区域伪影水平最高。当使用预饱和时,放置在这些区域(前后方向相位编码的横断面扫描中的前壁、室间隔和后壁)的轨迹可重复性提高了两倍(P <.001)。在与心腔不一致的区域(例如,横断面扫描中外侧壁的前侧),预饱和的效果不显著。这些结果与测得的伪影水平降低密切相关。当使用预饱和时,心脏大面积区域心肌运动轨迹的可重复性提高到约1毫米。因此,对于使用电影PC速度数据的心肌运动研究,建议使用预饱和。