Wiener spectrum of radiographic systems: comparison of different evaluation methods.

作者信息

Bregant P, De Denaro M, De Guarrini F, Borasi G

机构信息

Servizio di Fisica Sanitaria, A.S.S.N. 1, Trieste.

出版信息

Radiol Med. 1997 May;93(5):613-7.

PMID:9251741
Abstract

The noise power spectrum, or Wiener spectrum, of the radiographic mottle is a fundamental quantity in film-screen image quality evaluation. In this paper, using a high-quality computerized microdensitometer, two different acquisition and calculation methods for noise evaluation are compared. The first one is the classic (unidimensional) method used in film noise evaluation: a long and narrow slit (10 x 400 microns2) is used to delimit the microdensitometer light beam and the transmission data are collected by scanning the sample in a rectilinear pattern. A section of the two-dimensional Wiener spectrum is thus obtained. The second (two-dimensional) method is similar to that used in digital image noise evaluation: a square slit is used on the microdensitometer window and data are collected by scanning the sample on a square pattern. To evaluate the effect of different sampling frequencies, our data were acquired both selecting a 50 x 50 microns2 square slit and a 20 x 20 microns2 square slit. The two-dimensional Wiener spectrum thus obtained is then reduced to a unidimensional function. The measurements were made on two different films (Kodak Ortho G e Kodak T-MAT G) exposed with the same screen (Kodak Lanex Regular). These films have the same sensitivity but a different emulsion structure. One film (Ortho G) is made of irregular halide silver grains and the other (T-MAT G) of tabular grains. A satisfactory agreement between the two procedures was found which makes the comparison of data from the laboratories using microdensitometers and those using TV-grabbing system for film-screen evaluation meaningful.

摘要

相似文献

1
Wiener spectrum of radiographic systems: comparison of different evaluation methods.
Radiol Med. 1997 May;93(5):613-7.
2
A comparison of the imaging characteristics of the new Kodak Hyper Speed G film with the current T-MAT G/RA film and the CR 9000 system.新型柯达超高速G胶片与现行T-MAT G/RA胶片及CR 9000系统成像特性的比较。
Phys Med Biol. 2005 Oct 7;50(19):4541-52. doi: 10.1088/0031-9155/50/19/008. Epub 2005 Sep 13.
3
Radiographic screen-film noise power spectrum: variation with microdensitometer slit length.
Appl Opt. 1981 Aug 15;20(16):2795-8. doi: 10.1364/AO.20.002795.
4
[Evaluation of the quality of screen-film radiographic systems: physical principles and methods of measurement].[屏-片X线摄影系统质量评估:物理原理与测量方法]
Radiol Med. 1990 Sep;80(3):339-46.
5
[Structure of medical X-ray films].[医用X线胶片的结构]
Aichi Gakuin Daigaku Shigakkai Shi. 1990 Mar;28(1 Pt 1):195-202.
6
Assessment of radiographic screen-film systems: a comparison between the use of a microdensitometer and a drum film digitiser.
Radiat Prot Dosimetry. 2005;114(1-3):208-13. doi: 10.1093/rpd/nch563.
7
The choice of radiographic film-screen systems: quality evaluation and purchasing specifications drafting. Report on A.I.F.B. Working Group activity.X 线胶片-增感屏系统的选择:质量评估与采购规范起草。A.I.F.B. 工作组活动报告。
Radiol Med. 1993 May;85(5):662-7.
8
Evaluation of radiographs developed by a new ultrarapid film processing system.新型超快速胶片冲洗系统冲洗出的X光片评估
AJR Am J Roentgenol. 1990 May;154(5):1107-10. doi: 10.2214/ajr.154.5.2108553.
9
Technique charts for Kodak EC-L film screen system for portal localization in a 6MV X-ray beam.柯达EC-L胶片屏系统在6MV X射线束中用于射野定位的技术图表。
Technol Health Care. 2006;14(6):467-72.
10
[Investigation of simple Wiener spectrum measurement in medical imaging systems].[医学成像系统中简单维纳频谱测量的研究]
Zhongguo Yi Liao Qi Xie Za Zhi. 2006 Mar;30(2):136-8.