The purpose of this article is to evaluate the reliability and validity of stationary cystometry, stationary cysto-urethrometry and ambulatory cysto-urethro-vaginometry for the diagnosis of urinary incontinence.
Literature search on reproducibility of cystometry is based on articles written in the English language found in Medline from 1987 to 1993. Five articles were found. These articles had references for another 6 older articles about the same topic. One recently published article is evaluated as well. Data about reproducibility of cystometry performed in these studies are given. Knowledge of reproducibility of cystometry combined with urethrometry, urethro-vagino or rectometry with leak detection during stationary or ambulatory recording is given. An evaluation of validity of the different methods is presented.
Conflicting data has been found for sensory parameters of stationary cystometry such as volume or pressure at first desire to void, strong desire to void and maximum cystometric capacity. No data were found concerning the reliability of cystometry for the recording of urinary incontinence. The main problem of urge-incontinent patients is leakage with a strong feeling of urgency. The recording of sensory parameters by cystometry is not valid when the main problem is urge incontinence. Cystometry will be valid for the diagnosis of urge incontinence when a leak detector is used or a mark is made at the tracings when leakage is observed. The reliability of cystometry concerning urge incontinence should be documented. The reliability of a urethral pressure recording when the urethral catheter is extracorporally fixed is low. The reliability and validity of ambulatory cysto-urethro-vaginometry in diagnosing urge incontinence, unstable urethra and genuine stress incontinence seems to be good, but needs better documentation.
本文旨在评估静态膀胱测压法、静态膀胱尿道测压法及动态膀胱尿道阴道测压法在尿失禁诊断中的可靠性和有效性。
关于膀胱测压法可重复性的文献检索基于1987年至1993年在医学在线数据库(Medline)中检索到的英文文章。共找到5篇文章。这些文章还引用了另外6篇关于同一主题的更早的文章。同时也对一篇最近发表的文章进行了评估。给出了这些研究中所进行的膀胱测压法可重复性的数据。介绍了膀胱测压法与尿道测压法、尿道阴道或直肠测压法相结合在静态或动态记录期间进行漏尿检测的可重复性知识。对不同方法的有效性进行了评估。
对于静态膀胱测压法的感觉参数,如首次有排尿欲望时的容量或压力、强烈排尿欲望时的容量或压力以及最大膀胱测压容量,已发现相互矛盾的数据。未找到关于膀胱测压法记录尿失禁可靠性的数据。急迫性尿失禁患者的主要问题是伴有强烈紧迫感的漏尿。当主要问题是急迫性尿失禁时,通过膀胱测压法记录感觉参数是无效的。当使用漏尿检测器或在观察到漏尿时在描记图上做标记时,膀胱测压法对于急迫性尿失禁的诊断将是有效的。应记录膀胱测压法关于急迫性尿失禁的可靠性。当尿道导管体外固定时,尿道压力记录的可靠性较低。动态膀胱尿道阴道测压法在诊断急迫性尿失禁、不稳定尿道及真性压力性尿失禁方面的可靠性和有效性似乎较好,但需要更好的记录。