OBJECTIVE

To evaluate the reliability of oxygen saturation and oxygen content values measured from jugular venous blood in estimating values measured from mixed venous blood during endotoxic shock.

ANIMALS

14 random-bred 10- to 15-kg Yorkshire pigs.

PROCEDURE

60 pairs of heparinized blood samples were simultaneously collected from the pulmonary artery and right jugular vein during an independent study, using a porcine model of endotoxic shock. Endotoxic shock was induced by infusion of Escherichia coli endotoxin. Eighteen of the sample pairs were obtained from pigs prior to infusion of endotoxin or from control pigs. Oxygen saturation and venous oxygen content were measured by direct oximetry. Analysis of bias and precision was used to compare jugular venous blood values with values obtained from mixed venous blood. Samples from endotoxemic pigs were subclassified on the basis of abnormal states of global oxygen imbalance associated with septic shock.

RESULTS

Indices of venous oxygenation measured from jugular venous blood were an imprecise method of estimating values measured from mixed venous blood. There was no significant difference in bias between nonendotoxemic and endotoxemic pigs, regardless of abnormal hemodynamic states.

CONCLUSION

Jugular venous blood oxygen saturation and oxygen content values should not be used to assess global oxygen transport during endotoxic shock.

摘要

目的

评估在内毒素休克期间,通过颈静脉血测量的氧饱和度和氧含量值,在估算混合静脉血测量值方面的可靠性。

动物

14只随机繁育的10至15千克约克夏猪。

实验步骤

在一项独立研究中,使用内毒素休克猪模型,同时从肺动脉和右颈静脉采集60对肝素化血样。通过输注大肠杆菌内毒素诱导内毒素休克。其中18对样本是在给猪输注内毒素之前采集的,或者是从对照猪采集的。通过直接血氧测定法测量氧饱和度和静脉血氧含量。采用偏差和精密度分析,将颈静脉血值与混合静脉血值进行比较。根据与脓毒症休克相关的整体氧失衡异常状态,对来自内毒素血症猪的样本进行亚分类。

结果

通过颈静脉血测量的静脉氧合指标,是估算混合静脉血测量值的一种不精确方法。无论血流动力学状态是否异常,非内毒素血症猪和内毒素血症猪之间的偏差均无显著差异。

结论

在内毒素休克期间,不应使用颈静脉血氧饱和度和氧含量值来评估整体氧输送情况。