Ultrasonographic assessment of amniotic fluid does not reflect actual amniotic fluid volume.

作者信息

Chauhan S P, Magann E F, Morrison J C, Whitworth N S, Hendrix N W, Devoe L D

机构信息

Department of Obstetrics and Gynecology, Medical College of Georgia, Augusta 30912-3350, USA.

出版信息

Am J Obstet Gynecol. 1997 Aug;177(2):291-6; discussion 296-7. doi: 10.1016/s0002-9378(97)70189-3.

Abstract

OBJECTIVE

Our objective was to compare the ability of two methods of amniotic fluid assessment (two-diameter amniotic fluid pocket versus the amniotic fluid index) to predict oligohydramnios (actual amniotic fluid volume < 500 ml) or polyhydramnios (actual amniotic fluid volume > 1500 ml).

STUDY DESIGN

The amniotic fluid index and the two-diameter amniotic fluid pocket were assessed before amniocentesis and determination of amniotic fluid volume with the dye (aminohippurate sodium)-dilution technique. To assess the detection of either oligohydramnios or polyhydramnios, the areas under the receiver-operator characteristic curves (+/-SE) were estimated by the point-to-point trapezoidal method of integration. Prediction limits were calculated by regression analysis of amniotic fluid index or two-diameter amniotic fluid pocket versus actual amniotic fluid volume and determination of 95th percentile ranges for amniotic fluid volume.

RESULTS

We studied 144 patients with a mean (+/-SD) gestational age of 31.7 +/- 5.5 weeks; mean (+/-SD) amniotic fluid index and two-diameter amniotic fluid pocket were 12.6 +/- 6.1 cm and 21.2 +/- 18.4 cm2, respectively. Mean (+/-SD) actual amniotic fluid volume was 722 +/- 735 ml (range 101 to 4318 ml). The areas under the four receiver-operator characteristic curves were not significantly different from the nondiagnostic line (p < 0.05). Regression slopes (r values) for amniotic fluid index and two-diameter amniotic fluid pocket versus actual amniotic fluid volume were 0.34 and 0.23, respectively. Calculation of the prediction limit for 95% confidence that oligohydramnios is absent requires that the amniotic fluid index be 30 cm and the two-dimension amniotic fluid pocket be 90 cm2, both thresholds of which are currently considered to represent clinical polyhdramnios.

CONCLUSIONS

Both amniotic fluid index and two-dimension amniotic fluid pocket appear to be inaccurate predictors of actual oligohydramnios or polyhydramnios when compared with dye-dilution calculations of actual amniotic fluid volume.