A high-performance liquid chromatographic method for measuring amino acids in pig plasma has been developed by using 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate as a precolumn derivatization reagent. With the method presented here it was possible to separate 24 amino acids in pig plasma within one single run in 45 min, while only 18 amino acids were properly separated with the original AccQ.Tag conditions used for analysis of hydrolysate samples. The recovery was above 90% for most amino acids, and the mean coefficient of variation of the retention times below 0.30%. The within- and between-assay reproducibility for the determination of plasma amino acids showed C.V.s below 2.2% and 4.5%, respectively, for most amino acids analyzed. In the present work, most of the plasma amino acids were assayed with high sensitivity, accuracy and good reproducibility in a relatively short time and on very small amounts of sample.

摘要

已开发出一种高效液相色谱法,使用6-氨基喹啉-N-羟基琥珀酰亚胺基甲酸酯作为柱前衍生试剂来测定猪血浆中的氨基酸。采用本文介绍的方法,能够在45分钟内单次运行分离猪血浆中的24种氨基酸,而在用于分析水解产物样品的原始AccQ.Tag条件下,只能正确分离18种氨基酸。大多数氨基酸的回收率高于90%,保留时间的平均变异系数低于0.30%。对于所分析的大多数氨基酸,血浆氨基酸测定的批内和批间重现性的变异系数分别低于2.2%和4.5%。在本研究中,大多数血浆氨基酸能够在相对较短的时间内,使用极少量样品进行高灵敏度、准确且重现性良好的测定。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验