Fuentes V L, Moran C M, Schober K, McEwan J D, Brown H, Sutherland G R, McDicken W N
Department of Veterinary Clinical Studies, Royal (Dick) School of Veterinary Studies, University of Edinburgh, Summerhall, United Kingdom.
Am J Vet Res. 1997 Oct;58(10):1055-9.
To assess the feasibility and repeatability of measuring ultrasonic integrated backscatter in unsedated conscious dogs, using a protocol previously validated in pigs with open thorax.
11 clinically normal conscious unsedated German Shorthair Pointers.
A modified commercially available echocardiography system was used to record long-axis views of the heart. The radiofrequency data from 15 consecutive frames were digitized and analyzed. Regions of interest were chosen within the myocardium, and the ultrasonic integrated backscatter within each region was calculated in the time domain for each frame.
Cyclic variation in integrated backscatter values was observed, with maximal values at end-diastole and minimal values at end-systole. Mean +/-SD amplitude of cyclic variation was 5.81 +/- 3.86 dB over all the regions chosen.
Results agreed with those obtained by other investigators working with dogs with open thorax and those with closed thorax while under general anesthesia. The analysis of the components of variance indicates that this is a consistent, reliable technique in conscious unsedated dogs.
Integrated ultrasonic backscatter measurement provides a noninvasive means of tissue characterization. Use of this protocol reliably yields cyclic variation in integrated backscatter and could be applied clinically to dogs with myocardial disease.
使用先前在开胸猪身上验证过的方案,评估在未镇静的清醒犬中测量超声背向散射积分的可行性和可重复性。
11只临床健康、未镇静的清醒德国短毛指示犬。
使用改良的商用超声心动图系统记录心脏的长轴视图。对连续15帧的射频数据进行数字化分析。在心肌内选择感兴趣区域,并在时域中计算每一帧每个区域内的超声背向散射积分。
观察到背向散射积分值的周期性变化,舒张末期达到最大值,收缩末期达到最小值。在所选择的所有区域中,周期性变化的平均±标准差幅度为5.81±3.86dB。
结果与其他研究人员在开胸犬和全身麻醉下闭胸犬身上获得的结果一致。方差成分分析表明,这是一种在未镇静的清醒犬中一致、可靠的技术。
超声背向散射积分测量提供了一种无创的组织特征描述方法。使用该方案可可靠地产生背向散射积分的周期性变化,并可临床应用于患有心肌疾病的犬。